A time-domain method for the analysis of thermal impedance response preserving the convolution form

Fecha de publicación

2009-06-17T09:05:06Z

2009-06-17T09:05:06Z

1999

Resumen

The study of the thermal behavior of complex packages as multichip modules (MCM¿s) is usually carried out by measuring the so-called thermal impedance response, that is: the transient temperature after a power step. From the analysis of this signal, the thermal frequency response can be estimated, and consequently, compact thermal models may be extracted. We present a method to obtain an estimate of the time constant distribution underlying the observed transient. The method is based on an iterative deconvolution that produces an approximation to the time constant spectrum while preserving a convenient convolution form. This method is applied to the obtained thermal response of a microstructure as analyzed by finite element method as well as to the measured thermal response of a transistor array integrated circuit (IC) in a SMD package.

Tipo de documento

Artículo


Versión publicada

Lengua

Inglés

Publicado por

IEEE

Documentos relacionados

Reproducció del document publicat a http://dx.doi.org/10.1109/6144.774738

IEEE Transactions on Components Packaging and Manufacturing Technology Part A, 1999, vol. 22, núm. 2, p. 238-244 .

http://dx.doi.org/10.1109/6144.774738

http://dx.doi.org/10.1109/6144.774738

Citación recomendada

Esta citación se ha generado automáticamente.

Derechos

(c) IEEE, 1999