2009-06-17T09:05:06Z
2009-06-17T09:05:06Z
1999
The study of the thermal behavior of complex packages as multichip modules (MCM¿s) is usually carried out by measuring the so-called thermal impedance response, that is: the transient temperature after a power step. From the analysis of this signal, the thermal frequency response can be estimated, and consequently, compact thermal models may be extracted. We present a method to obtain an estimate of the time constant distribution underlying the observed transient. The method is based on an iterative deconvolution that produces an approximation to the time constant spectrum while preserving a convenient convolution form. This method is applied to the obtained thermal response of a microstructure as analyzed by finite element method as well as to the measured thermal response of a transistor array integrated circuit (IC) in a SMD package.
Article
Versió publicada
Anglès
Circuits integrats; Convolucions (Matemàtica); Mètodes iteratius (Matemàtica); Convolution; Finite element analysis; Integrated circuit packaging; Iterative methods; Multichip modules; Thermal model; Thermal resistance; Time-domain analysis
IEEE
Reproducció del document publicat a http://dx.doi.org/10.1109/6144.774738
IEEE Transactions on Components Packaging and Manufacturing Technology Part A, 1999, vol. 22, núm. 2, p. 238-244 .
http://dx.doi.org/10.1109/6144.774738
http://dx.doi.org/10.1109/6144.774738
(c) IEEE, 1999