Resumen

Leakage detection is an important issue in many chemical sensing applications. Leakage detection hy thresholds suffers from important drawbacks when sensors have serious drifts or they are affected by cross-sensitivities. Here we present an adaptive method based in a Dynamic Principal Component Analysis that models the relationships between the sensors in the may. In normal conditions a certain variance distribution characterizes sensor signals. However, in the presence of a new source of variance the PCA decomposition changes drastically. In order to prevent the influence of sensor drifts the model is adaptive and it is calculated in a recursive manner with minimum computational effort. The behavior of this technique is studied with synthetic signals and with real signals arising by oil vapor leakages in an air compressor. Results clearly demonstrate the efficiency of the proposed method.

Tipo de documento

Artículo


Versión publicada

Lengua

Inglés

Materias y palabras clave

Detectors de gasos; Gas detectors; Electronic noise

Publicado por

IEEE

Documentos relacionados

Reproducció del document publicat a http://dx.doi.org/10.1109/ICSENS.2003.1279065

IEEE Sensors Journal, 2003, vol. 2, núm. 22-24, p. 860-865.

http://dx.doi.org/10.1109/ICSENS.2003.1279065