dc.description.abstract
The purpose of this study is to assess the use of grade V titanium mini transitional implants(MTIs) immediately loaded by a temporary overdenture. For this, a histomorphometric analysisof the bone area fraction occupancy (BAFO) was performed by backscattered scanning electronmicroscopy (BS-SEM). Four female patients were submitted to surgery in which two MTIs wereinstalled and immediately loaded with a temporary acrylic prosthesis. During the same surgery,two regular diameter implants were placed inside the bone and maintained without mechanical load.After 8 months, the MTIs were extracted using a trephine and processed for ultrastructural boneanalysis by BS-SEM, and the regular-diameter implants were loaded with an overdenture device.A total of 243 BAFOs of MTIs were analyzed, of which 94 were mainly filled with cortical bone,while 149 were mainly filled with trabecular bone. Bone tissue analysis considering the total BAFOswith calcified tissues showed 72.13% lamellar bone, 26.04% woven bone, and 1.82% chondroid bonewithout significant differences between the samples. This study revealed that grade V titanium usedin immediately loaded MTI was successfully osseointegrated by a mature and vascularized bonetissue as assessed from the BAFO.
dc.format
8 p.
dc.format
application/pdf
dc.format
application/pdf
dc.language
eng
dc.publisher
MDPI
dc.relation
Reproducció del document publicat a: https://doi.org/10.3390/met11010002
dc.relation
Metals, 2020, vol. 11, num. 1, p. 2-9
dc.relation
https://doi.org/10.3390/met11010002
dc.rights
cc-by (c) Beltrán, Víctor et al., 2020
dc.rights
http://creativecommons.org/licenses/by/3.0/es
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Patologia i Terapèutica Experimental)
dc.subject
Titani
dc.subject
Implants dentals
dc.subject
Electrons
dc.subject
Titanium
dc.subject
Dental implants
dc.subject
Electrones
dc.title
Histomorphometric analysis of osseointegrated grade V titanium mini transitional implants inEdentulous mandible by backscattered scanning electron microscopy (BS-SEM)
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)