Robustness analysis of sensor placement for leak detection and location under uncertain operating conditions

dc.contributor
Universitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial
dc.contributor
Universitat Politècnica de Catalunya. SIC - Sistemes Intel·ligents de Control
dc.contributor
Universitat Politècnica de Catalunya. SAC - Sistemes Avançats de Control
dc.contributor.author
Blesa Izquierdo, Joaquim
dc.contributor.author
Nejjari Akhi-Elarab, Fatiha
dc.contributor.author
Sarrate Estruch, Ramon
dc.date.issued
2014
dc.identifier
Blesa, J.; Nejjari, F.; Sarrate, R. Robustness analysis of sensor placement for leak detection and location under uncertain operating conditions. A: Water Distribution Systems Analysis Conference. "Prceedings of the 16th Water Distribution System Analysis Conference, WDSA2014". Bari: 2014, p. 1553-1560.
dc.identifier
https://hdl.handle.net/2117/26571
dc.identifier
10.1016/j.proeng.2014.11.453
dc.description.abstract
Some pressure sensor placement methods for leak detection and location in water distribution networks are based on the pressure sensitivity matrix analysis. This matrix depends on the network demands, which are nondeterministic, and the leak magnitudes, which are unknown. In this paper, the robustness of a sensor placement methodology against the fault sensitivity matrix uncertainty is studied. The robustness study is illustrated by means of a small academic network as well as a district metered area in the Barcelona water distribution network. Results reveal that this uncertainty should be taken into account in the sensor placement methodology.
dc.description.abstract
Peer Reviewed
dc.description.abstract
Postprint (published version)
dc.format
8 p.
dc.format
application/pdf
dc.language
eng
dc.relation
http://dx.doi.org/10.1016/j.proeng.2014.11.453
dc.relation
info:eu-repo/grantAgreement/EC/FP7/318556/EU/Efficient Integrated Real-time Monitoring and Control of Drinking Water Networks/EFFINET
dc.rights
Open Access
dc.subject
Àrees temàtiques de la UPC::Informàtica::Automàtica i control
dc.subject
Observation (Scientific method)
dc.subject
Robust control
dc.subject
Water - Distribution
dc.subject
observability
dc.subject
sensor placement
dc.subject
leak location
dc.subject
clustering
dc.subject
robustness analysis
dc.subject
Observació (Mètode científic)
dc.subject
Control de robustesa
dc.subject
Aigua--Distribució
dc.title
Robustness analysis of sensor placement for leak detection and location under uncertain operating conditions
dc.type
Conference report


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

E-prints [72954]