Robustness analysis of sensor placement for leak detection and location under uncertain operating conditions

Other authors

Universitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial

Universitat Politècnica de Catalunya. SIC - Sistemes Intel·ligents de Control

Universitat Politècnica de Catalunya. SAC - Sistemes Avançats de Control

Publication date

2014

Abstract

Some pressure sensor placement methods for leak detection and location in water distribution networks are based on the pressure sensitivity matrix analysis. This matrix depends on the network demands, which are nondeterministic, and the leak magnitudes, which are unknown. In this paper, the robustness of a sensor placement methodology against the fault sensitivity matrix uncertainty is studied. The robustness study is illustrated by means of a small academic network as well as a district metered area in the Barcelona water distribution network. Results reveal that this uncertainty should be taken into account in the sensor placement methodology.


Peer Reviewed


Postprint (published version)

Document Type

Conference report

Language

English

Related items

http://dx.doi.org/10.1016/j.proeng.2014.11.453

info:eu-repo/grantAgreement/EC/FP7/318556/EU/Efficient Integrated Real-time Monitoring and Control of Drinking Water Networks/EFFINET

Recommended citation

This citation was generated automatically.

Rights

Open Access

This item appears in the following Collection(s)

E-prints [72986]