Institut Català de la Salut
[Giralt M, Ferrer R, Díaz-Troyano N] Servei de Bioquímica, Vall d’Hebron Hospital Universitari, Barcelona, Spain. Grup de Bioquímica Clínica, Vehiculització de Fàrmacs i Teràpia, Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Barcelona, Spain. [Vega B, Luque-Ramírez M] Department of Endocrinology & Nutrition, Hospital Universitario Ramón y Cajal & Universidad de Alcalá & Instituto Ramón y Cajal de Investigación Sanitaria (IRYCIS) & Centro. [Martínez S] Servei d’Anàlisis Clíniques i Bioquímica, Hospital Germans Trias i Pujol, Barcelona, Spain. [Cardona I] Servei de Farmàcia, Vall d’Hebron Hospital Universitari, Barcelona, Spain
Vall d'Hebron Barcelona Hospital Campus
2025-09-22T07:18:07Z
2025-09-22T07:18:07Z
2025-07
Exemestane; Immunoassay; Liquid chromatography-mass spectrometry
Exemestano; Inmunoensayo; Cromatografía líquida-espectrometría de masas
Exemestà; Immunoassaig; Cromatografia líquida-espectrometria de masses
Background: Exemestane, an aromatase inhibitor commonly used for breast cancer treatment, shares structural similarities with sex steroids analyzed in clinical laboratories. We aimed to investigate the influence of exemestane cross-reactivity in the measurement of sex steroids across various immunoassays. Methods: We conducted a multicenter study involving measurements of androstenedione, testosterone, estradiol, progesterone, and 17-hydroxyprogesterone in serum samples from women undergoing exemestane therapy (N=15; 25 mg/day). Measurements were performed using liquid chromatography-mass spectrometry (LC-MS) and various commercially available chemiluminescence immunoassays, ELISA, and radioimmunoassay. In-vitro cross-reactivity was assessed by adding exemestane and 17-hydroexemestane to serum samples. Results: Patients undergoing exemestane therapy had markedly falsely elevated androstenedione results in all immunoassays evaluated (N=4), which correlated with serum exemestane levels. In-vitro experiments confirmed this interference to be caused by cross-reactivity with exemestane. Additionally, one immunoassay yielded falsely elevated estradiol results in 20% of patients. However, in-vitro experiments did not confirm this to be caused by cross-reactivity with exemestane or 17-hydroexemestane. Conclusions: Exemestane cross-reacts with androstenedione immunoassays, causing falsely elevated results in treated patients. This analytical interference may raise unnecessary concerns, leading to expensive diagnostic workups.
Article
Versió publicada
Anglès
Mama - Càncer - Tractament; Enzims - Inhibidors - Ús terapèutic; Immunoassaig; Cromatografia de líquids; CHEMICALS AND DRUGS::Chemical Actions and Uses::Pharmacologic Actions::Molecular Mechanisms of Pharmacological Action::Enzyme Inhibitors::Steroid Synthesis Inhibitors::Aromatase Inhibitors; Other subheadings::Other subheadings::/therapeutic use; DISEASES::Neoplasms::Neoplasms by Site::Breast Neoplasms; Other subheadings::Other subheadings::Other subheadings::/drug therapy; ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Investigative Techniques::Immunologic Techniques::Immunoassay; ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Investigative Techniques::Chemistry Techniques, Analytical::Chromatography::Chromatography, Liquid; COMPUESTOS QUÍMICOS Y DROGAS::acciones y usos químicos::acciones farmacológicas::mecanismos moleculares de acción farmacológica::inhibidores enzimáticos::inhibidores de la síntesis esteroidea::inhibidores de la aromatasa; Otros calificadores::Otros calificadores::/uso terapéutico; ENFERMEDADES::neoplasias::neoplasias por localización::neoplasias de la mama; Otros calificadores::Otros calificadores::Otros calificadores::/farmacoterapia; TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::técnicas de investigación::técnicas inmunológicas::inmunoanálisis; TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::técnicas de investigación::técnicas de química analítica::cromatografía::cromatografía líquida
Korean Society for Laboratory Medicine
Annals of Laboratory Medicine;45(4)
https://doi.org/10.3343/alm.2024.0362
Attribution-NonCommercial 4.0 International
http://creativecommons.org/licenses/by-nc/4.0/
Articles científics - VHIR [1655]