To access the full text documents, please follow this link: http://hdl.handle.net/2117/99618
dc.contributor | Universitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial |
---|---|
dc.contributor | Universitat Politècnica de Catalunya. BIOSPIN - Biomedical Signal Processing and Interpretation |
dc.contributor.author | Estrada Petrocelli, Luis |
dc.contributor.author | Torres Cebrián, Abel |
dc.contributor.author | Garcia Casado, Javier |
dc.contributor.author | Sarlabous Uranga, Leonardo |
dc.contributor.author | Prats Boluda, Gema |
dc.contributor.author | Jané Campos, Raimon |
dc.date | 2016 |
dc.identifier.citation | Estrada, L., Torres, A., Garcia, J., Sarlabous, L., Prats, G., Jane, R. Time-frequency representations of the sternocleidomastoid muscle electromyographic signal recorded with concentric ring electrodes. A: Annual International Conference of the IEEE Engineering in Medicine and Biology Society. "2016 38th annual international conference of the IEEE Engineering in Medicine and Biology Society (EMBC)". Orlando, FL: Institute of Electrical and Electronics Engineers (IEEE), 2016, p. 3785-3788. |
dc.identifier.citation | 978-1-4577-0220-4 |
dc.identifier.citation | 10.1109/EMBC.2016.7591552 |
dc.identifier.uri | http://hdl.handle.net/2117/99618 |
dc.language.iso | eng |
dc.publisher | Institute of Electrical and Electronics Engineers (IEEE) |
dc.relation | http://ieeexplore.ieee.org/document/7591552/?reload=true |
dc.rights | info:eu-repo/semantics/openAccess |
dc.rights | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ |
dc.subject | Àrees temàtiques de la UPC::Enginyeria biomèdica |
dc.subject | Biomedical engineering |
dc.subject | biomedical electrodes |
dc.subject | electromyography |
dc.subject | exponential distribution |
dc.subject | medical signal detection |
dc.subject | medical signal processing |
dc.subject | pneumodynamics |
dc.subject | signal representation |
dc.subject | signal resolution |
dc.subject | timefrequency analysis |
dc.subject | Wigner distribution |
dc.subject | sternocleidomastoid muscle electromyographic signal |
dc.subject | noninvasive methods |
dc.subject | respiratory muscle signals |
dc.subject | respiratory muscle function |
dc.subject | electrical activity |
dc.subject | concentric ring electrodes |
dc.subject | bipolar configuration |
dc.subject | spatial resolution |
dc.subject | interference attenuation |
dc.subject | electrode location |
dc.subject | respiratory load test |
dc.subject | inspiratory load |
dc.subject | inspiratory phase |
dc.subject | orientation problem |
dc.subject | inspiratory mouth pressure |
dc.subject | electromyographic signal acquisition |
dc.subject | EMGsc signal |
dc.subject | spectrogram |
dc.subject | Morlet scalogram |
dc.subject | Wigner-Ville distribution |
dc.subject | Choi-Williams distribution |
dc.subject | generalized exponential distributions |
dc.subject | Born-Jordan distribution |
dc.subject | Cone-Kernel distribution |
dc.subject | bilinear time-frequency representations |
dc.subject | cardiac activity interference |
dc.subject | Enginyeria biomèdica |
dc.title | Time-frequency representations of the sternocleidomastoid muscle electromyographic signal recorded with concentric ring electrodes |
dc.type | info:eu-repo/semantics/publishedVersion |
dc.type | info:eu-repo/semantics/conferenceObject |
dc.description.abstract | |
dc.description.abstract |