Mercury (II) and methylmercury determination in waters by liquid chromatography hyphenated to cold vapour atomic fluorescence spectrometry after online short-column preconcentration

dc.contributor.author
Carneado Moreno, Sergio
dc.contributor.author
Peró Gascón, Roger
dc.contributor.author
Ibáñez Palomino, Carmen
dc.contributor.author
López Sánchez, José Fermín
dc.contributor.author
Sahuquillo Estrugo, Àngels
dc.date.issued
2015-07-13T08:33:34Z
dc.date.issued
2016-02-09T23:01:42Z
dc.date.issued
2015-02-09
dc.date.issued
2015-07-13T08:33:34Z
dc.identifier
1759-9660
dc.identifier
https://hdl.handle.net/2445/66291
dc.identifier
648482
dc.description.abstract
This paper reports a method developed for the simultaneous determination of methylmercury (MeHg+) and mercury(II) (Hg2+) species in water by liquid chromatography coupled to online UV irradiation and cold vapour atomic fluorescence spectrometry (LC-UV-CV-AFS) after online short-column preconcentration. This work focused on systematic studies of several variables to establish the maximum species recoveries, preconcentration factors and good reproducibility. The optimum results obtained were the following: 0.07 mmol L 1 2-mercaptoethanol as a complexing agent, precolumn conditioning with the mobile phase: a mixture of 80% of methanol (MeOH) and 20% of the following buffer: 0.0015 mol L 1 ammonium pyrrolidine dithiocarbamate (APDC) and 0.01 mol L 1 ammonium acetate (NH4CH3COO) at pH 5.5, 2 cm precolumn length and 2 mL min 1 sample flow. This method was applied to three water samples with different mineralisation contents. Various tests, based on spikes, were performed on each sample. A breakthrough volume of 4 mL was found. The recovery values of 72 3% and 81 5% for MeHg+ and Hg2+, respectively, were obtained regardless of the matrix composition, and the PF values were 30 and 32 for MeHg+ and Hg2+, respectively. The accuracy of the preconcentration method was verified by analysing a certified reference material. The detection limits (LDs) obtained were 15 ng L 1 for MeHg+ and 2 ng L 1 for Hg2+. The quantification limits (LQs) were 50 ng L 1 for both species. The established analytical online preconcentration method is suitable for the quantification of mercury species in a wide range of environmental waters.
dc.format
8 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
Royal Society of Chemistry
dc.relation
Versió postprint del document publicat a: http://dx.doi.org/10.1039/c4ay02929a
dc.relation
Analytical Methods, 2015, vol. 7, p. 2699-2706
dc.relation
http://dx.doi.org/10.1039/c4ay02929a
dc.rights
(c) Carneado, S. et al., 2015
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject
Mercuri
dc.subject
Cromatografia de líquids
dc.subject
Contaminació de l'aigua
dc.subject
Metilmercuri
dc.subject
Mercury
dc.subject
Liquid chromatography
dc.subject
Water pollution
dc.subject
Methylmercury
dc.title
Mercury (II) and methylmercury determination in waters by liquid chromatography hyphenated to cold vapour atomic fluorescence spectrometry after online short-column preconcentration
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/acceptedVersion


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)