dc.contributor.author
Serrano Suárez, Alejandra
dc.contributor.author
Dellundé, Jordi
dc.contributor.author
Salvadó i Cabré, Humbert
dc.contributor.author
Cervero Aragó, Sílvia
dc.contributor.author
Méndez Viera, Javier
dc.contributor.author
Canals, Oriol
dc.contributor.author
Blanco, Silvia
dc.contributor.author
Arcas Pons, Antoni
dc.contributor.author
Araujo Boira, Rosa Ma.
dc.date.accessioned
2026-03-03T02:14:57Z
dc.date.available
2026-03-03T02:14:57Z
dc.date.issued
2026-03-02T12:38:39Z
dc.date.issued
2026-03-02T12:38:39Z
dc.date.issued
2013-02-23
dc.date.issued
2026-03-02T12:38:39Z
dc.identifier
https://hdl.handle.net/2445/227735
dc.identifier.uri
https://hdl.handle.net/2445/227735
dc.description.abstract
Hot water recirculation systems (HWRS) in hotels and nursing homes, which are common in countries such as Spain, have been related to outbreaks of legionellosis. To establish the relationships of microbial and physicochemical parameters, especially protozoa, with the occurrence of Legionella in HWRS, 231 samples from hotels and nursing homes were analysed for Legionella, protozoa, heterotrophic plate counts (HPC) at 22 and 37 °C, Pseudomonas, metals, temperature and others. Legionella pneumophila was the dominant species isolated, and 22 % were sg. 1. The sampling method became particularly important in order to define which factors were involved on the occurrence of Legionella. Results showed that the bacteria and the accompanying microbiota were more abundant in the first flush water whose temperature was lower. The bacteria occurred in those samples with high HPC and were inversely correlated with high temperatures. Multivariate regression showed that a concentration above 1× 105CFU/100 mL of HPC at 37 °C, Fe above 0.095 ppm and the presence of protozoa increased significantly the risk of Legionella colonization, while univariant regression showed that the presence of Cu above 0.76 ppm and temperature above 55 °C diminished it. Therefore, to reduce the risk associated with Legionella occurrence in HWRS these parameters should be taken into consideration.
dc.format
application/pdf
dc.publisher
Springer Verlag
dc.relation
Versió postprint del document publicat a: https://doi.org/10.1007/s11356-013-1557-5
dc.relation
Environmental Science and Pollution Research, 2013, vol. 20, p. 5534-5544
dc.relation
https://doi.org/10.1007/s11356-013-1557-5
dc.rights
(c) Springer Verlag, 2013
dc.rights
info:eu-repo/semantics/openAccess
dc.subject
Contaminació microbiana
dc.subject
Microbiologia aquàtica
dc.subject
Microbial contamination
dc.subject
Water microbiology
dc.title
Microbial and physicochemical parameters associated with Legionella contamination in hot water recirculation systems
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/acceptedVersion