In-vitro mechanical performance of three CAD-CAM bar designs for implant-supported metal-resin hybrid prostheses: a preliminary pilot study

dc.contributor.author
Arteaga-Losada, Lorena
dc.contributor.author
Laura-Fernadez, Héctor
dc.contributor.author
Puerta-Dominguez, María Alejandra
dc.contributor.author
Ascaso-Terren, Carlos
dc.contributor.author
Vives i Santa-Eulàlia, Eduard
dc.contributor.author
Escuin-Henar, Tomás
dc.contributor.author
Torné-Durán, Sergi
dc.date.accessioned
2026-01-24T19:58:07Z
dc.date.available
2026-01-24T19:58:07Z
dc.date.issued
2026-01-23T14:05:27Z
dc.date.issued
2026-01-23T14:05:27Z
dc.date.issued
2026-01-20
dc.date.issued
2026-01-23T14:05:27Z
dc.identifier
2212-4268
dc.identifier
https://hdl.handle.net/2445/226042
dc.identifier
764178
dc.identifier.uri
https://hdl.handle.net/2445/226042
dc.description.abstract
Background Implant-supported hybrid metal–resin prostheses are widely used to rehabilitate edentulous patients. However, fractures of the veneering resin and screw complications remain common mechanical failures. Advances in CAD-CAM design and laser sintering technology may improve the structural integrity of these restorations. Aims To conduct a preliminary in-vitro evaluation of the fracture resistance of veneering resin in three CAD-CAM–designed bar configurations fabricated by laser sintering, describing their mechanical behavior and failure patterns under compressive stress. Methods Three bar designs (inverted T, L-shaped, and Ackerman circular) were digitally created and manufactured in cobalt–chromium using laser sintering. Each bar was veneered with autopolymerizing acrylic resin and subjected to compressive loading up to 1000 N at a 30° angle, in accordance with ISO 14801. Simultaneously, acoustic emission analysis was performed to detect microcracks and structural failures. Results No fractures of the veneering resin were observed. Mechanical failures occurred as deformation or fracture of prosthetic screws, beginning at 600 N. Acoustic emission detected early microcracks between 160 N and 400 N, and main fracture peaks between 627 N and 871 N. Among the three samples, the inverted T-shaped bar sustained the highest load before failure in this pilot test. Conclusion In this pilot in-vitro study, the veneering resin showed high resistance under simulated masticatory loading. The combination of CAD-CAM design, laser-sintered fabrication, and retentive elements may enhance mechanical performance. Further studies with larger sample sizes and cyclic loading are warranted to validate these preliminary findings.
dc.format
6 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
Elsevier B.V.
dc.relation
Reproducció del document publicat a: https://doi.org/10.1016/j.jobcr.2026.101407
dc.relation
Journal of Oral Biology and Craniofacial Research, 2026, vol. 16, num.101407, p. 1-6
dc.relation
https://doi.org/10.1016/j.jobcr.2026.101407
dc.rights
cc-by (c) Arteaga-Losada, Lorena et al., 2026
dc.rights
http://creativecommons.org/licenses/by/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.subject
Implants dentals
dc.subject
Sistemes CAD-CAM
dc.subject
Materials dentals
dc.subject
Dental implants
dc.subject
CAD/CAM systems
dc.subject
Dental materials
dc.title
In-vitro mechanical performance of three CAD-CAM bar designs for implant-supported metal-resin hybrid prostheses: a preliminary pilot study
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Fitxers en aquest element

FitxersGrandàriaFormatVisualització

No hi ha fitxers associats a aquest element.

Aquest element apareix en la col·lecció o col·leccions següent(s)