Development and validation of an LC-MS/MS method for the simultaneous detection of urinary inflammatory biomarkers in a Flemish birth cohort

dc.contributor.author
Raes, Jeroen
dc.contributor.author
Vanhaecke, Lynn
dc.contributor.author
Nawrot, Tim S.
dc.contributor.author
Covaci, Adrian
dc.contributor.author
Ouden, Fatima den
dc.contributor.author
Cseresznye, Adam
dc.contributor.author
Engelen, Liesa
dc.contributor.author
Maris, Elias
dc.contributor.author
Paepe, Ellen De
dc.contributor.author
Poma, Giulia
dc.contributor.author
Proost, Sebastian
dc.contributor.author
Vich Vila, Arnau
dc.contributor.author
Hemeryck, Lieselot Y.
dc.contributor.author
Peró Gascón, Roger
dc.contributor.author
De Saeger, Sarah
dc.date.accessioned
2026-01-17T04:05:24Z
dc.date.available
2026-01-17T04:05:24Z
dc.date.issued
2026-01-16T15:23:30Z
dc.date.issued
2026-01-15
dc.date.issued
2026-01-16T15:23:31Z
dc.date.issued
info:eu-repo/date/embargoEnd/2028-01-14
dc.identifier
1570-0232
dc.identifier
https://hdl.handle.net/2445/225644
dc.identifier
763893
dc.identifier.uri
http://hdl.handle.net/2445/225644
dc.description.abstract
Chronic inflammation is a significant contributor to various diseases but its assessment via blood sampling presents challenges, particularly in children. The evaluation of urinary biomarkers, including 3-bromotyrosine (Bty), 3-chlorotyrosine (Cty) and leukotriene E4 (LTE4), offers a non-invasive alternative. This study presents the optimization and validation of a sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantification of Bty, Cty and LTE4 in urine. Under optimized conditions, sample preparation was based on SPE using Oasis MAX cartridges, followed by LC-MS/MS analysis. Method performance was validated using the ICH 10 guidelines, resulting in satisfactory results for all analytes in terms of recovery, linearity, limits of quantification, precision and accuracy. Recovery rates ranged from 82% to 97%, while matrix effects were observed within the range of -11% to 26%.  Linear range spanned from 0.08 to 20 ng/mL for the three analytes. Application to 332 urine samples from the ENVIR<em>ON</em>AGE birth cohort (Belgium), comprising of children aged 4–11 years, revealed detection frequencies of 18% for LTE4, 19% for Cty and 50% for Bty. Notably, creatinine-corrected Cty and LTE4 exhibited statistically significant Spearman correlations with established systemic inflammation markers. Specifically, Cty was positively correlated with absolute monocyte count (ρ = 0.53, <em>p</em> < 0.05), while LTE4 showed a positive correlation with relative eosinophil levels (ρ = 0.46, <em>p</em> < 0.05) and a negative  correlation with the relative neutrophil levels (ρ = -0.56, <em>p</em> < 0.01). These results highlight the validated method as a valuable tool for investigating distinct inflammatory pathways in epidemiological settings and clinical research.
dc.format
9 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
Elsevier B.V.
dc.relation
Versió postprint del document publicat a: https://doi.org/10.1016/j.jchromb.2025.124867
dc.relation
Journal Of Chromatography B-Analytical Technologies In The Biomedical And Life Sciences, 2026, vol. 1269
dc.relation
https://doi.org/10.1016/j.jchromb.2025.124867
dc.rights
cc-by-nc-nd (c) Elsevier B.V., 2026
dc.rights
http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rights
info:eu-repo/semantics/embargoedAccess
dc.subject
Inflamació
dc.subject
Orina
dc.subject
Pediatria
dc.subject
Inflammation
dc.subject
Urine
dc.subject
Pediatrics
dc.title
Development and validation of an LC-MS/MS method for the simultaneous detection of urinary inflammatory biomarkers in a Flemish birth cohort
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/acceptedVersion


Fitxers en aquest element

FitxersGrandàriaFormatVisualització

No hi ha fitxers associats a aquest element.