A novel technique for computer-assisted dental autotransplantation: A case report with 42 months of follow-up

dc.contributor.author
Chegeni, Ehsan
dc.contributor.author
Marques, José
dc.contributor.author
Barbosa de Figueiredo, Rui Pedro
dc.contributor.author
Valmaseda Castellón, Eduardo
dc.contributor.author
Kadkhodazadeh, Mahdi
dc.date.accessioned
2025-12-13T09:59:40Z
dc.date.available
2025-12-13T09:59:40Z
dc.date.issued
2025-12-12T17:49:42Z
dc.date.issued
2025-12-12T17:49:42Z
dc.date.issued
2025-04-13
dc.date.issued
2025-12-12T17:49:42Z
dc.identifier
2645-5390
dc.identifier
https://hdl.handle.net/2445/224882
dc.identifier
760193
dc.identifier
40673116
dc.identifier.uri
http://hdl.handle.net/2445/224882
dc.description.abstract
Dental autotransplantation (DAT) is an effective technique for replacing missing teeth. This case report presents a novel computer-assisted approach using cone-beam computed tomography (CBCT) for 3D planning. A 15-year-old female with a hopeless molar due to failed endodontic treatment underwent DAT. Following 3D planning, the donor tooth was surgically extracted and transplanted into the prepared socket, followed by semi-rigid splinting. A meticulous 42-month clinical and radiographic follow-up demonstrated the success and stability of the procedure. This innovative method emphasizes the role of advanced computer technology and 3D imaging in enhancing surgical precision and treatment outcomes. Within the limitations of this case report, DAT, combined with computer-assisted planning, proved a reliable and predictable treatment option for replacing hopeless teeth, particularly in young patients. This approach showed the potential of DAT to transform tooth replacement strategies with better accuracy and decision-making.
dc.format
8 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
Tabriz University of Medical Sciences (TUOMS)
dc.relation
Reproducció del document publicat a: https://doi.org/10.34172/japid.025.3760
dc.relation
Journal of Advanced Periodontology and Implant Dentistry (JAPID), 2025, vol. 17, num.2, p. 111-118
dc.relation
https://doi.org/10.34172/japid.025.3760
dc.rights
cc-by (c) Chegeni, E. et al., 2025
dc.rights
http://creativecommons.org/licenses/by/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.subject
Autotrasplantament
dc.subject
Implants dentals
dc.subject
Queixal del seny
dc.subject
Autotransplantation
dc.subject
Dental implants
dc.subject
Wisdom tooth
dc.title
A novel technique for computer-assisted dental autotransplantation: A case report with 42 months of follow-up
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Fitxers en aquest element

FitxersGrandàriaFormatVisualització

No hi ha fitxers associats a aquest element.

Aquest element apareix en la col·lecció o col·leccions següent(s)