Impact of autoclaving on the dimensional stability of 3D-Printed surgical guides for aesthetic crown lengthening

dc.contributor.author
González-Barnadas, Albert
dc.contributor.author
Ribas-Garcia, Anna
dc.contributor.author
Jorba García, Adrià
dc.contributor.author
Barbosa de Figueiredo, Rui Pedro
dc.contributor.author
Valmaseda Castellón, Eduardo
dc.contributor.author
Camps Font, Octavi
dc.date.issued
2025-09-10T17:32:08Z
dc.date.issued
2025-09-10T17:32:08Z
dc.date.issued
2025-08-02
dc.date.issued
2025-09-10T17:32:08Z
dc.identifier
2079-4983
dc.identifier
https://hdl.handle.net/2445/223109
dc.identifier
760199
dc.identifier
40863304
dc.description.abstract
The aim of this study was to evaluate the impact of autoclaving on the dimensional stability of surgical guides (SGs) for aesthetic crown lengthening (ACL) using different resins/printing methods. Fifty SGs for ACL were printed using five different resin/printer combinations (FL, SR, ND, KS and VC). All the SGs were scanned before (T0) and after (T1) sterilization. Autoclaving was conducted at 134 °C during 4 min. The STL files of each SG at T0 and T1 were compared with the original design (TR). Dimensional stability was measured using trueness and precision. Deviations from TR to T1 were calculated in the three space axes and by measuring the area between three reference landmarks. At T0, the FL group showed the best trueness and precision, while the SR group performed significantly worse than the other groups. At T1, all the groups except VC exhibited significant dimensional alterations compared with T0. Also, VC showed the best trueness and precision values. All the groups had a significant deviation in at least one space axis, while only the SR group exhibited significant variations from T1 to TR in the area between the reference landmarks. Most of the evaluated resin/3D printer combinations suffered significant dimensional alterations after autoclaving.
dc.format
13 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
MDPI
dc.relation
Reproducció del document publicat a: https://doi.org/10.3390/jfb16080284
dc.relation
Journal of Functional Biomaterials, 2025, vol. 16, num.8, p. 284-284
dc.relation
https://doi.org/10.3390/jfb16080284
dc.rights
cc-by (c) González-Barnadas, A. et al., 2025
dc.rights
http://creativecommons.org/licenses/by/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Odontoestomatologia)
dc.subject
Impressió 3D
dc.subject
Odontologia estètica
dc.subject
Cirurgia oral
dc.subject
Three-dimensional printing
dc.subject
Dental aesthetic
dc.subject
Oral surgery
dc.title
Impact of autoclaving on the dimensional stability of 3D-Printed surgical guides for aesthetic crown lengthening
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)