dc.contributor.author
Muñoz Mahamud, Ernesto
dc.contributor.author
Chimeno, Clara
dc.contributor.author
Fernández-Valencia, J. A. (Jenaro-Ángel)
dc.contributor.author
Alías, Alfonso
dc.contributor.author
Serra, Adrià
dc.contributor.author
Postnikov, Yury
dc.contributor.author
Combalía Aleu, Andrés
dc.date.issued
2025-03-27T08:10:52Z
dc.date.issued
2025-03-27T08:10:52Z
dc.date.issued
2023-05-15
dc.date.issued
2025-03-27T08:10:52Z
dc.identifier
https://hdl.handle.net/2445/220053
dc.description.abstract
Purpose: Failure to restore the femoral offset of the native hip is a potential cause of dysfunctional hip arthroplasty. The aim of this study was to report our experience of using a modular head-neck adapter in revision THA, specifically analyzing its usefulness as a tool to correct a slightly diminished femoral offset. Materials and methods: This was a retrospective single-center study including all hip revisions performed at our institution from January 2017 to March 2022 where the BioBallTM head-neck metal adapter was used. The preoperative and one year follow-up modified Merle d'Aubigné hip score was used to evaluate functional outcomes. Results: Of a total of 34 cases included for revision, the head-neck adapter system was used specifically in six patients (17.6%) to increase femoral offset, retaining both the acetabular and femoral components. In this subgroup of patients, mean offset decrease after primary THA was 6.6 mm (4.0-9.1), equivalent to a mean 16.3% femoral offset reduction. The median modified Merle d'Aubigné score went from 13.3 preoperatively to 16.2 at one year follow-up. Conclusion: The use of a head-neck adapter is a safe and reliable procedure that may allow the surgeon to easily correct a slightly diminished femoral offset in a dysfunctional THA without the need to revise well-fixed prosthetic components.
dc.format
application/pdf
dc.publisher
Springer Verlag
dc.relation
Reproducció del document publicat a: https://doi.org/10.1007/s00264-023-05833-7
dc.relation
International Orthopaedics, 2023, vol. 47, p. 2245-2251
dc.relation
https://doi.org/10.1007/s00264-023-05833-7
dc.rights
cc by (c) Muñoz Mahamud, Ernesto et al., 2023
dc.rights
https://creativecommons.org/licenses/by/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)
dc.subject
Cirurgia ortopèdica
dc.subject
Cirurgia dels ossos
dc.subject
Orthopedic surgery
dc.subject
Surgery of bones
dc.title
Contribution of the BioballTM head-neck adapter to the restoration of femoral offset in hip revision arthroplasty with retention of a well-fixed cup and stem
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion