Over the most recent decades, the development of new biological platforms to study disease progression and drug efficacy has been of great interest due to the high increase in the rate of neurodegenerative diseases (NDDs). Therefore, blood–brain barrier (BBB) as an organ-on-a-chip (OoC) platform to mimic brain-barrier performance could offer a deeper understanding of NDDs as well as a very valuable tool for drug permeability testing for new treatments. A very attractive improvement of BBB-oC technology is the integration of detection systems to provide continuous monitoring of biomarkers in real time and a fully automated analysis of drug permeably, rendering more efficient platforms for commercialization. In this Perspective, an overview of the main BBB-oC configurations is introduced and a critical vision of the BBB-oC platforms integrating electronic read out systems is detailed, indicating the strengths and weaknesses of current devices, proposing the great potential for biosensors integration in BBB-oC. In this direction, we name potential biomarkers to monitor the evolution of NDDs related to the BBB and/or drug cytotoxicity using biosensor technology in BBB-oC.
Article
Published version
English
Elèctrodes; Biosensors; Biotecnologia; Electrodes; Biosensors; Biotechnology
American Chemical Society
Reproducció del document publicat a: https://doi.org/10.1021/acssensors.2c00333
ACS Sensors, 2022, vol. 7, num.5, p. 1237-1247
https://doi.org/10.1021/acssensors.2c00333
cc-by (c) Mir, Mònica, et al., 2022
http://creativecommons.org/licenses/by/3.0/es/