Miró Meda, José M. (José María), 1956-
Tolosana, José M. (José María)
Hospital Clínic of Barcelona Infective Endocarditis Team Investigators
2024-04-02T16:04:20Z
2024-04-05T05:10:10Z
2023-04-06
2024-04-02T16:04:25Z
Introduction and objectives: The role of [18F]FDG-PET/CT in cardiac implantable electronic device (CIED) infections requires better evaluation, especially in the diagnosis of systemic infections. We aimed to determine the following: a) the diagnostic accuracy of [18F]FDG-PET/CT in each CIED topographical region, b) the added value of [18F]FDG-PET/CT over transesophageal echocardiography (TEE) in diagnosing systemic infections, c) spleen and bone marrow uptake in differentiating isolated local infections from systemic infections, and d) the potential application of [18F]FDG-PET/CT in follow-up. Methods: Retrospective single-center study including 54 cases and 54 controls from 2014 to 2021. The Primary endpoint was the diagnostic yield of [18F]FDG-PET/CT in each topographical CIED region. Secondary analyses described the performance of [18F]FDG-PET/CT compared with that of TEE in systemic infections, bone marrow and spleen uptake in systemic and isolated local infections, and the potential application of [18F]FDG-PET/CT in guiding cessation of chronic antibiotic suppression when completed device removal is not performed. Results: We analyzed 13 (24%) isolated local infections and 41 (76%) systemic infections. Overall, the specificity of [18F]FDG-PET/CT was 100% and sensitivity 85% (79% pocket, 57% subcutaneous lead, 22% endovascular lead, 10% intracardiac lead). When combined with TEE, [18F]FDG-PET/CT increased definite diagnosis o fsystemic infections from 34% to 56% (P=.04). Systemic infections with bacteremia showed higher spleen (P=.05) and bone marrow metabolism (P=.04) than local infections. Thirteen patients without complete device removal underwent a follow-up [18F]FDG-PET/CT, with no relapses after discontinuation of chronic antibiotic suppression in 6 cases with negative follow-up [18F]FDG-PET/CT. Conclusions: The sensitivity of [18F]FDG-PET/CT for evaluating CIED infections was high in local infections but much lower in systemic infections. However, accuracy increased when [18F]FDG-PET/CT was combined with TEE in endovascular lead bacteremic infection. Spleen and bone marrow hypermetabolism could differentiate bacteremic systemic infection from local infection. Although further prospective studies are needed, follow-up [18F]FDG-PET/CT could play a potential role in the management of chronic antibiotic suppression therapy when complete device removal is unachievable.
Article
Accepted version
English
Endocarditis; Marcapassos; Infeccions; Desfibril·ladors cardioversors implantables; Endocarditis; Cardiac pacemakers; Infections; Implantable cardioverter-defibrillators
Elsevier España
Versió postprint del document publicat a: https://doi.org/10.1016/j.rec.2023.04.001
Revista Española de Cardiologia, 2023, vol. 76, num.12, p. 970-979
https://doi.org/10.1016/j.rec.2023.04.001
cc-by-nc-nd (c) Elsevier España, 2023
http://creativecommons.org/licenses/by-nc-nd/4.0/