Chiroptical measurement of chiral aggregates at liquid-liquid interface in centrifugal liquid membrane cell by Mueller matrix and conventional circular dichroism methods

dc.contributor.author
Takechi, Hideaki
dc.contributor.author
Arteaga Barriel, Oriol
dc.contributor.author
Ribó i Trujillo, Josep M.
dc.contributor.author
Watarai, Hitoshi
dc.date.issued
2011-11-15T10:03:42Z
dc.date.issued
2011-11-15T10:03:42Z
dc.date.issued
2011-04-29
dc.identifier
1420-3049
dc.identifier
https://hdl.handle.net/2445/20724
dc.identifier
595010
dc.description.abstract
The centrifugal liquid membrane (CLM) cell has been utilized for chiroptical studies of liquid-liquid interfaces with a conventional circular dichroism (CD) spectropolarimeter. These studies required the characterization of optical properties of the rotating cylindrical CLM glass cell, which was used under the high speed rotation. In the present study, we have measured the circular and linear dichroism (CD and LD) spectra and the circular and linear birefringence (CB and LB) spectra of the CLM cell itself as well as those of porphyrine aggregates formed at the liquid-liquid interface in the CLM cell, applying Mueller matrix measurement method. From the results, it was confirmed that the CLM-CD spectra of the interfacial porphyrin aggregates observed by a conventional CD spectropolarimeter should be correct irrespective of LD and LB signals in the CLM cell.
dc.format
12 p.
dc.format
application/pdf
dc.format
application/pdf
dc.language
eng
dc.publisher
MDPI Publishing
dc.relation
Reproducció del document publicat a: http://dx.doi.org/10.3390/molecules16053636
dc.relation
Molecules, 2011, 16(5), 3636-3647
dc.relation
http://dx.doi.org/10.3390/molecules16053636
dc.rights
cc-by, (c) Takechi et al., 2011
dc.rights
http://creativecommons.org/licenses/by/3.0/es
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Química Inorgànica i Orgànica)
dc.subject
Quiralitat
dc.subject
Dicroisme circular
dc.subject
Refracció doble
dc.subject
Porfirines
dc.subject
Agregació (Química)
dc.subject
Chirality
dc.subject
Circular dichroism
dc.subject
Double refraction
dc.subject
Porphyrins
dc.subject
Aggregation (Chemistry)
dc.title
Chiroptical measurement of chiral aggregates at liquid-liquid interface in centrifugal liquid membrane cell by Mueller matrix and conventional circular dichroism methods
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)