dc.contributor.author
Frade Sosa, Beatriz
dc.contributor.author
Ponce, Andrés
dc.contributor.author
Inciarte Mundo, José
dc.contributor.author
Morla, Rosa
dc.contributor.author
Ruíz Esquide, Virginia
dc.contributor.author
Macías Muñoz, Laura
dc.contributor.author
Azuaga, Ana Belén
dc.contributor.author
Ramírez, Julio
dc.contributor.author
Cañete Crespillo, Juan D.
dc.contributor.author
Yagüe, Jordi
dc.contributor.author
Auge, Josep Maria
dc.contributor.author
Gómez Puerta, José A.
dc.contributor.author
Sanmartí Sala, Raimon
dc.date.issued
2024-01-29T19:26:53Z
dc.date.issued
2024-01-29T19:26:53Z
dc.date.issued
2023-06-28T08:45:26Z
dc.identifier
https://hdl.handle.net/2445/206552
dc.description.abstract
To analyse the accuracy of plasma calprotectin in patients with rheumatoid arthritis (RA) receiving monoclonal antibodies against IL-6 receptors (anti-rIL-6) or JAK inhibitors (JAKis) in detecting ultrasound (US) synovitis and compare it with acute phase reactants [high-sensitivity C-reactive protein (hs-CRP) and ESR].An observational cross-sectional study of RA patients receiving anti-rIL-6 (tocilizumab or sarilumab) or JAKi, (baricitinib or tofacitinib) was made. Plasma calprotectin for the diagnosis of US synovitis [synovial hypertrophy grade (SH)???2 plus power Doppler signal (PD)???1] was analysed using receiver operating characteristic curves (ROCs). The performance of ESR and hs-CRP was also studied. The three ROC curves were compared to determine which had the highest discriminatory power. Associations between plasma calprotectin and US scores were made using correlation analysis.Sixty-three RA patients were included. Mean plasma calprotectin levels were significantly higher in patients with US synovitis than in those without (0.89?±?0.85 vs 0.30?±?0.12 ?g/ml; p?=?0.0003). A moderate correlation between calprotectin and all US scores (HS score Rho?=?0.479; PD score Rho?=?0.492; and global score Rho?=?0.495) was found. The discriminatory capacity of plasma calprotectin showed an AUC of 0.795 (95% CI: 0.687-0.904). The AUC of hs-CRP and ESR was 0.721 and 0.564, respectively. hs-CRP serum levels showed a low positive correlation with the three US scores (Rho?<?0.40). After analysis according to the drugs administered, the correlation disappeared in patients receiving anti-rIL-6.Plasma calprotectin may be a sensitive biomarker of synovial inflammation in RA patients treated with anti-rIL-6 or JAKi.© The Author(s), 2022.
dc.format
application/pdf
dc.format
application/pdf
dc.relation
Reproducció del document publicat a: https://doi.org/10.1177/1759720x221114105
dc.relation
Therapeutic Advances In Musculoskeletal Disease, 2022, vol. 14
dc.relation
https://doi.org/10.1177/1759720x221114105
dc.rights
cc by-nc (c) Frade Sosa, Beatriz et al., 2022
dc.rights
http://creativecommons.org/licenses/by-nc/3.0/es/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (IDIBAPS: Institut d'investigacions Biomèdiques August Pi i Sunyer)
dc.subject
Artritis reumatoide
dc.subject
Anàlisi de proteïnes
dc.subject
Rheumatoid arthritis
dc.subject
Analysis of proteins
dc.title
Plasma calprotectin as a biomarker of ultrasound synovitis in rheumatoid arthritis patients receiving IL-6 antagonists or JAK inhibitors
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion