dc.contributor.author
Wu, Vincen
dc.contributor.author
Tillner, Jocelyn
dc.contributor.author
Jones, Emrys
dc.contributor.author
McKenzie, James S
dc.contributor.author
Gurung, Dipa
dc.contributor.author
Mroz, Anna
dc.contributor.author
Poynter, Liam
dc.contributor.author
Simon, Daniel
dc.contributor.author
Grau, Cristina
dc.contributor.author
Altafaj, Xavier
dc.contributor.author
Dumas, Marc-Emmanuel
dc.contributor.author
Gilmore, Ian
dc.contributor.author
Bunch, Josephine
dc.contributor.author
Takats, Zoltan
dc.date.issued
2023-03-01T16:35:56Z
dc.date.issued
2022-07-19
dc.date.issued
2023-03-01T16:35:56Z
dc.identifier
https://hdl.handle.net/2445/194393
dc.description.abstract
In this study, we examine the suitability of desorption electro-flow focusing ionization (DEFFI) for mass spectrometry imaging (MSI) of biological tissue. We also compare the performance of desorption electrospray ionization (DESI) with and without the flow focusing setup. The main potential advantages of applying the flow focusing mechanism in DESI is its rotationally symmetric electrospray jet, higher intensity, more controllable parameters, and better portability due to the robustness of the sprayer. The parameters for DEFFI have therefore been thoroughly optimized, primarily for spatial resolution but also for intensity. Once the parameters have been optimized, DEFFI produces similar images to the existing DESI. MS images for mouse brain samples, acquired at a nominal pixel size of 50 μm, are comparable for both DESI setups, albeit the new sprayer design yields better sensitivity. Furthermore, the two methods are compared with regard to spectral intensity as well as the area of the desorbed crater on rhodamine-coated slides. Overall, the implementation of a flow focusing mechanism in DESI is shown to be highly suitable for imaging biological tissue and has potential to overcome some of the shortcomings experienced with the current geometrical design of DESI.
dc.format
application/pdf
dc.publisher
American Chemical Society
dc.relation
Reproducció del document publicat a: https://doi.org/10.1021/acs.analchem.2c00345
dc.relation
Analytical Chemistry, 2022, vol. 94, num. 28, p. 10035-10044
dc.relation
https://doi.org/10.1021/acs.analchem.2c00345
dc.rights
cc-by (c) Wu, Vincen et al., 2022
dc.rights
http://creativecommons.org/licenses/by/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Biomedicina)
dc.subject
Diagnòstic per la imatge
dc.subject
Espectrometria de masses
dc.subject
Espectrometria de masses amb ionització per electroesprai
dc.subject
Ratolins (Animals de laboratori)
dc.subject
Diagnostic imaging
dc.subject
Mass spectrometry
dc.subject
Electrospray ionization mass spectrometry
dc.subject
Mice (Laboratory animals)
dc.title
High resolution ambient MS imaging of biological samples by desorption electro-flow focussing ionization
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion