Non-rigid alignment pipeline applied to human gait signals acquired with optical motion capture systems and inertial sensors

dc.contributor.author
Soussé, Rubén
dc.contributor.author
Verdú, Jorge
dc.contributor.author
Jauregui, Ricardo
dc.contributor.author
Ferrer-Roca, Ventura
dc.contributor.author
Balocco, Simone
dc.date.issued
2023-02-09T09:36:57Z
dc.date.issued
2023-02-09T09:36:57Z
dc.date.issued
2020-01-02
dc.date.issued
2023-02-09T09:36:57Z
dc.identifier
0021-9290
dc.identifier
https://hdl.handle.net/2445/193323
dc.identifier
692985
dc.description.abstract
An accurate gait characterization is fundamental for diagnosis and treatment in both clinical and sportive fields. Although several devices allow such measurements, the performance comparison between the acquired signals may be a challenging task. A novel pipeline for the accurate non-rigid alignment of gait signals is proposed. In this paper, the measurements of Inertial Measurement Units (IMU) and Optical Motion Capture Systems (OMCAP) are aligned using a modified version of the Dynamic Time Warping (DTW) algorithm. The differences between the two acquisitions are evaluated using both global (RMSE, Correlation Coefficient (CC)) and local (Statistical Parametric Mapping (SPM)) metrics. The method is applied to a data-set obtained measuring the gait of ten healthy subjects walking on a treadmill at three different gait paces. Results show a global bias between the signal acquisition of 0.05°. Regarding the global metrics, a mean RMSE value of 2.65° (0.73°) and an average CC value of 0.99 (0.01) were obtained. The SPM profile shows, in each gait cycle phase, the percentage of cases when two curves are statistically identical and reaches an average of 48% (22%).
dc.format
17 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
Elsevier B.V.
dc.relation
Versió postprint del document publicat a: https://doi.org/10.1016/j.jbiomech.2019.109429
dc.relation
Journal of Biomechanics, 2020, vol. 98
dc.relation
https://doi.org/10.1016/j.jbiomech.2019.109429
dc.rights
cc-by-nc-nd (c) Elsevier B.V., 2020
dc.rights
https://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Matemàtiques i Informàtica)
dc.subject
Cinemàtica
dc.subject
Optoelectrònica
dc.subject
Algorismes computacionals
dc.subject
Kinematics
dc.subject
Optoelectronics
dc.subject
Computer algorithms
dc.title
Non-rigid alignment pipeline applied to human gait signals acquired with optical motion capture systems and inertial sensors
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/acceptedVersion


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)