Feasibility of 4D-Spatio Temporal Image Correlation (STIC) in the Comprehensive Assessment of the Fetal Heart Using FetalHQ®.

dc.contributor.author
Nogué i Garrigolas, Laura
dc.contributor.author
Masoller Casas, Narcís
dc.contributor.author
Martínez, Josep Maria
dc.contributor.author
Gómez, Olga
dc.contributor.author
Gratacós Solsona, Eduard
dc.contributor.author
Crispi Brillas, Fàtima
dc.contributor.author
Bennasar Sans, Mª del Mar
dc.contributor.author
Izquierdo, Nora
dc.contributor.author
Mula, Cristina
dc.contributor.author
Devore, Greggory
dc.date.issued
2022-06-21T11:17:47Z
dc.date.issued
2022-06-21T11:17:47Z
dc.date.issued
2022-03-04
dc.identifier
2077-0383
dc.identifier
https://hdl.handle.net/2445/186865
dc.identifier
729394
dc.identifier
9300510
dc.identifier
35268505
dc.identifier
256408
dc.description.abstract
Fetal Heart Quantification (FetalHQ®) is a novel speckle tracking software that permits the study of global and regional ventricular shape and function from a 2D four-chamber-view loop. The 4D-Spatio Temporal Image Correlation (STIC) modality enables the offline analysis of optimized and perfectly aligned cardiac planes. We aimed to evaluate the feasibility and reproducibility of 4D-STIC speckle tracking echocardiography (STE) using FetalHQ® and to compare it to 2D STE. We conducted a prospective study including 31 low-risk singleton pregnancies between 20 and 40 weeks of gestation. Four-chamber view volumes and 2D clips were acquired with an apex pointing at 45° and with a frame rate higher than 60 Hz. Morphometric and functional echocardiography was performed by FetalHQ®. Intra- and interobserver reproducibility were evaluated by the intraclass correlation coefficient (ICC). Our results showed excellent reproducibility (ICC > 0.900) for morphometric evaluation (biventricular area, longitudinal and transverse diameters). Reproducibility was also good (ICC > 0.800) for functional evaluation (biventricular strain, Fractional Area Change, left ventricle volumes, ejection fraction and cardiac output). On the contrary, the study of the sphericity index and shortening fraction of the different ventricular segments showed lower reproducibility (ICC < 0.800). To conclude, 4D-STIC is feasible, reproducible and comparable to 2D echocardiography for the assessment of cardiac morphometry and function.
dc.format
17 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
MDPI
dc.relation
Reproducció del document publicat a: https://doi.org/10.3390/jcm11051414
dc.relation
Journal of Clinical Medicine, 2022, vol. 11, num. 5
dc.relation
https://doi.org/10.3390/jcm11051414
dc.rights
cc by (c) Nogué, Laura et al, 2022
dc.rights
http://creativecommons.org/licenses/by/3.0/es/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)
dc.subject
Electrocardiografia
dc.subject
Fetus
dc.subject
Electrocardiography
dc.subject
Fetus
dc.title
Feasibility of 4D-Spatio Temporal Image Correlation (STIC) in the Comprehensive Assessment of the Fetal Heart Using FetalHQ®.
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Fitxers en aquest element

FitxersGrandàriaFormatVisualització

No hi ha fitxers associats a aquest element.