Mixtures of chelating agents to enhance photo-Fenton process at natural pH: Influence of wastewater matrix on micropollutant removal and bacterial inactivation

dc.contributor.author
López Vinent, Núria
dc.contributor.author
Cruz Alcalde, Alberto
dc.contributor.author
Giménez, Jaime
dc.contributor.author
Esplugas Vidal, Santiago
dc.date.issued
2021-12-22T18:00:12Z
dc.date.issued
2021-12-22T18:00:12Z
dc.date.issued
2021-04-29
dc.date.issued
2021-12-22T18:00:12Z
dc.identifier
0048-9697
dc.identifier
https://hdl.handle.net/2445/181950
dc.identifier
712127
dc.description.abstract
Three organic fertilizers (EDTA (Ethylenedinitrilotetraacetic acid), EDDS (Ethylenediamine-N, N′-disuccinic acid) and DTPA (Diethylene triamine pentaacetic acid)) were tested as Fe-complexes in photo-Fenton process at natural pH for micropollutants (MPs) abatement and simultaneous E.coli inactivation. Less stable Fe-complexes show high iron precipitation, stopping MPs degradation. On the contrary, stable Fe-complexes imply low kinetic rates for MPs removal. To solve these inconveniences, three mixtures of organic fertilizers were also tested, trying to improve the kinetic rates of micropollutants oxidation and overcome iron precipitation. Three different pollutants (propranolol (PROP), acetamiprid (ACMP) and sulfamethoxazole (SMX)) were used as the target compounds. As the iron release is, in part, linked to the hardness of water, two water matrices from two different secondary wastewaters (Membrane Bioreactor (MBR) and Conventional Activated Sludge (CAS)) were tested. The best performance in micropollutant degradation and E.coli inactivation was achieved with the combination of EDDS + EDTA, accomplishing a good equilibrium between iron precipitation and rate of MPs removal. For instance, total removal of propranolol was achieved at 45 min in MBR, while it was only 85.7% in CAS, being an improvement of the process comparing with that obtained using single organic fertilizers. At the end of the treatment, 2.1 log-inactivation for E.coli was reached in CAS. The differences observed between both wastewaters were related to CAS' higher DOC, turbidity, and hardness. Finally, from the physicochemical characterization conducted, including Biochemical Oxygen Demand at 5 days and phytotoxicity, it is possible to highlight the suitability of these treated effluents for its reuse in irrigation, as long as in CAS matrix the final values of E. coli are within the legal limit.
dc.format
application/pdf
dc.language
eng
dc.publisher
Elsevier B.V.
dc.relation
Reproducció del document publicat a: https://doi.org/10.1016/j.scitotenv.2021.147416
dc.relation
Science of the Total Environment, 2021, vol. 786, p. 147416
dc.relation
https://doi.org/10.1016/j.scitotenv.2021.147416
dc.rights
cc-by-nc-nd (c) López Vinent et al, 2021
dc.rights
https://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject
Aigües residuals
dc.subject
Fotoquímica
dc.subject
Contaminants
dc.subject
Sewage
dc.subject
Photochemistry
dc.subject
Pollutants
dc.title
Mixtures of chelating agents to enhance photo-Fenton process at natural pH: Influence of wastewater matrix on micropollutant removal and bacterial inactivation
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)