dc.contributor.author
Moreno Morales, Javier
dc.contributor.author
Vergara Gómez, Andrea
dc.contributor.author
Kostyanev, Tomislav
dc.contributor.author
Rodríguez Baño, Jesús
dc.contributor.author
Goossens, Herman
dc.contributor.author
Vila Estapé, Jordi
dc.date.issued
2021-04-22T10:36:22Z
dc.date.issued
2021-04-22T10:36:22Z
dc.date.issued
2021-01-13
dc.date.issued
2021-04-22T10:36:22Z
dc.identifier
https://hdl.handle.net/2445/176628
dc.description.abstract
Carbapenem-resistant Acinetobacter spp. mainly Acinetobacter baumannii are frequently causing nosocomial infections with high mortality. In this study, the efficacy of the Eazyplex® SuperBug Complete A system, based on loop-mediated isothermal amplification (LAMP), to detect the presence of carbapenemases in Acinetobacter spp. directly from bronchoalveolar lavage (BAL) samples was assessed. A total of 22 Acinetobacter spp. strains producing OXA-23, OXA-40, OXA-58, NDM, and IMP were selected. Eazyplex SuperBug Complete A kit, used with the Genie II device, is a molecular diagnostics kit that detects a selection of genes that express carbapenemases (bla KPC , bla NDM , bla VIM , bla OXA-48 , bla OXA-23 , bla OXA-40 , and bla OXA-58 ). Negative BAL samples were identified, McFarland solutions were prepared from each of the 22 Acinetobacter strains and serial dilutions in saline solution were made to finally spike BAL samples to a concentration of 102 and 103 CFU/ml. Fifteen concentrations out of the 44 tested out did not provide detection of the carbapenemase-producing gene, all but one being at the lowest concentration tested at 102 CFU/ml; therefore, the limit of sensitivity is 103 CFU/ml. This assay represents the kind of advantages that investing in molecular diagnostics brings to the clinical practice, allowing the identification of carbapenemases in less than 30 min with a sensitivity of 103 CFU/ml.
dc.format
application/pdf
dc.publisher
Frontiers Media
dc.relation
Reproducció del document publicat a: https://doi.org/10.3389/fmicb.2020.597684
dc.relation
Frontiers in Microbiology, 2021, vol. 11, num. 597684
dc.relation
https://doi.org/10.3389/fmicb.2020.597684
dc.rights
cc-by (c) Moreno Morales, Javier et al., 2021
dc.rights
http://creativecommons.org/licenses/by/3.0/es
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Fonaments Clínics)
dc.subject
Infeccions nosocomials
dc.subject
Enterobacteriàcies
dc.subject
Nosocomial infections
dc.subject
Enterobacteriaceae
dc.title
Evaluation of a Loop-Mediated Isothermal Amplification Assay to Detect Carbapenemases Directly from Bronchoalveolar Lavage Fluid Spiked with Acinetobacter spp
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion