Competitive USB-Powered Hand-Held Potentiostat for POC Applications: An HRP Detection Case

dc.contributor.author
Montes Cebrián, Yaiza
dc.contributor.author
Álvarez Carulla, Albert
dc.contributor.author
Ruíz Vega, Gisela
dc.contributor.author
Colomer i Farrarons, Jordi
dc.contributor.author
Puig i Vidal, Manuel
dc.contributor.author
Baldrich, Eva
dc.contributor.author
Miribel-Català, Pere Ll. (Pere Lluís)
dc.date.issued
2021-04-09T13:58:53Z
dc.date.issued
2021-04-09T13:58:53Z
dc.date.issued
2019-12-06
dc.date.issued
2021-04-09T13:58:53Z
dc.identifier
1424-8220
dc.identifier
https://hdl.handle.net/2445/176150
dc.identifier
696885
dc.identifier
31817657
dc.description.abstract
Considerable efforts are made to develop Point-of-Care (POC) diagnostic tests. POC devices have the potential to match or surpass conventional systems regarding time, accuracy, and cost, and they are significantly easier to operate by or close to the patient. This strongly depends on the availability of miniaturized measurement equipment able to provide a fast and sensitive response. This paper presents a low-cost, portable, miniaturized USB-powered potentiostat for electrochemical analysis, which has been designed, fabricated, characterized, and tested against three forms of high-cost commercial equipment. The portable platform has a final size of 10.5 × 5.8 × 2.5 cm, a weight of 41 g, and an approximate manufacturing cost of $85 USD. It includes three main components: the power module which generates a stable voltage and a negative supply, the front-end module that comprises a dual-supply potentiostat, and the back-end module, composed of a microcontroller unit and a LabVIEW-based graphic user interface, granting plug-and-play and easy-to-use operation on any computer. The performance of this prototype was evaluated by detecting chronoamperometrically horseradish peroxidase (HRP), the enzymatic label most widely used in electrochemical biosensors. As will be shown, the miniaturized platform detected HRP at concentrations ranging from 0.01 ng·mL−1 to 1 µg·mL−1, with results comparable to those obtained with the three commercial electrochemical systems
dc.format
13 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
MDPI
dc.relation
Reproducció del document publicat a: https://doi.org/10.3390/s19245388
dc.relation
Sensors, 2019, vol. 19, num. 24, p. 5388
dc.relation
https://doi.org/10.3390/s19245388
dc.rights
cc-by (c) Montes Cebrián, Yaiza et al., 2019
dc.rights
http://creativecommons.org/licenses/by/3.0/es
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Enginyeria Electrònica i Biomèdica)
dc.subject
Biosensors
dc.subject
Ordinadors portàtils
dc.subject
Peroxidasa
dc.subject
Biosensors
dc.subject
Portable computers
dc.subject
Peroxidase
dc.title
Competitive USB-Powered Hand-Held Potentiostat for POC Applications: An HRP Detection Case
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)