Microneedle based electrochemical (bio)sensing: towards decentralized and continuous health status monitoring

dc.contributor.author
García-Guzmán, Juan José
dc.contributor.author
Pérez Ràfols, Clara
dc.contributor.author
Cuartero, María
dc.contributor.author
Crespo, Gastón A.
dc.date.issued
2021-02-10T14:17:38Z
dc.date.issued
2021-02-10T14:17:38Z
dc.date.issued
2020-12-10
dc.date.issued
2021-02-10T14:17:38Z
dc.identifier
0165-9936
dc.identifier
https://hdl.handle.net/2445/173835
dc.identifier
706906
dc.description.abstract
Microneedle (MN) based electrochemical (bio)sensing has become a growing field within the discipline of analytical chemistry as a result of its unique capacity for continuous, decentralized health status monitoring. There are two significant advantages to this exclusive feature: i) the ability to directly analyze interstitial fluid (ISF), a body fluid with a similar enough composition to plasma (and blood) to be considered a plentiful source of information related to biologically relevant molecules and biomarkers; and ii) the capacity to overcome some of the major limitations of blood analysis including painful extraction, high interferant concentrations, and incompatibility with diagnosis of infants (and especially newborns). Recent publications have demonstrated important advancements in electrochemical MN sensor technology, among which are included new MN fabrication methods and various modification strategies, providing different architectures and allowing for the integration of electronics. This versatility highlights the undeniable need for interdisciplinary efforts towards tangible progress in the field. In a context evidently dominated by glucose sensing, which is slowly being expanded towards other analytes, the following crucial questions arise: to what extent are electrochemical MN (bio)sensors a reliable analytical tool for continuous ISF monitoring? Which is the best calibration protocol to be followed for in vivo assays? Which strategies can be employed to protect the sensing element during skin penetration? Is there an appropriate validation methodology to assess the accuracy of electrochemical MN (bio)sensors? How significant is the distinction between successful achievements in the laboratory and the real commercial feasibility of products? This paper aims to reflect on those previous questions while reviewing the progress of electrochemical MN (bio)sensors in the last decade with a focus on the analytical aspects. Overall, we describe the current state of electrochemical MN (bio)sensors, the benefits and challenges associated to ISF monitoring, as well as key features (and bottlenecks) regarding its implementation for in vivo assays.
dc.format
30 p.
dc.format
application/pdf
dc.format
application/pdf
dc.language
eng
dc.publisher
Elsevier B.V.
dc.relation
Reproducció del document publicat a: https://doi.org/10.1016/j.trac.2020.116148
dc.relation
Trac-Trends in Analytical Chemistry, 2020, vol. 135, p. 116148
dc.relation
https://doi.org/10.1016/j.trac.2020.116148
dc.rights
cc-by-nc-nd (c) García-Guzmán, J.J., 2020
dc.rights
http://creativecommons.org/licenses/by/3.0/es/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject
Biosensors
dc.subject
Electroquímica
dc.subject
Assistència sanitària
dc.subject
Monitoratge de pacients
dc.subject
Biosensors
dc.subject
Electrochemistry
dc.subject
Medical care
dc.subject
Patient monitoring
dc.title
Microneedle based electrochemical (bio)sensing: towards decentralized and continuous health status monitoring
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)