Enantiodetermination of R,S-3,4-methylenedioxypyrovalerone in urine samples by high pressure in-line solid-phase extraction capillary electrophoresis-mass spectrometry

dc.contributor.author
Pérez-Alcaraz, Albert
dc.contributor.author
Borrull, Francesc
dc.contributor.author
Aguilar, Carme
dc.contributor.author
Calull, Marta
dc.contributor.author
Benavente Moreno, Fernando J. (Julián)
dc.date.issued
2021-01-18T10:27:18Z
dc.date.issued
2022-12-14T06:10:27Z
dc.date.issued
2020-12-14
dc.date.issued
2021-01-18T10:27:18Z
dc.identifier
0039-9140
dc.identifier
https://hdl.handle.net/2445/173106
dc.identifier
704991
dc.description.abstract
This study presents for the first time an in-line solid-phase extraction capillary electrophoresis-mass spectrometry (SPE-CE-MS) method for the enantiodetermination of drugs of abuse in urine samples. The enantioseparation of R,S-3,4-methylenedioxypyrovalerone (R,S-MDPV) was achieved with a 10 mM ammonium acetate BGE (pH 7) that contained 0.5% (m/v) of sulphated-α-CD as chiral selector. At these pH conditions, this CD was negatively charged, which prevented its entrance into the mass spectrometer since it migrates in the opposite direction. To improve sensitivity, an in-line SPE-CE-MS method using high pressure for sample introduction (i.e. 20 min at 3 bars) was developed. Furthermore, the conditioning procedure and the first part of the electrophoretic separation were performed by switching off the nebulizer gas and the ionization source voltage to avoid non-volatile contaminant arrival into the mass spectrometer. The developed methodology was validated by analyzing urine samples, which required a very simple liquid-liquid extraction (LLE) sample pretreatment. Linearity ranged from 30 to 250 ng/mL, limit of detection (LOD) was 10 ng/mL, relative standard deviation (RSD) values were below 10.5% in terms of intra-day and inter-day precision and the relative error values were below 9% for peak areas accuracy.
dc.format
application/pdf
dc.language
eng
dc.publisher
Elsevier B.V.
dc.relation
Versió postprint del document publicat a: https://doi.org/10.1016/j.talanta.2020.121994
dc.relation
Talanta, 2020, vol. 225, p. 121994
dc.relation
https://doi.org/10.1016/j.talanta.2020.121994
dc.rights
cc-by-nc-nd (c) Elsevier B.V., 2020
dc.rights
http://creativecommons.org/licenses/by-nc-nd/3.0/es
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject
Espectrometria de masses
dc.subject
Electroforesi capil·lar
dc.subject
Anàlisi d'orina
dc.subject
Mass spectrometry
dc.subject
Capillary electrophoresis
dc.subject
Urine analysis
dc.title
Enantiodetermination of R,S-3,4-methylenedioxypyrovalerone in urine samples by high pressure in-line solid-phase extraction capillary electrophoresis-mass spectrometry
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/acceptedVersion


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)