dc.contributor.author
Peró Gascón, Roger
dc.contributor.author
Benavente Moreno, Fernando J. (Julián)
dc.contributor.author
Neusüß, Christian
dc.contributor.author
Sanz Nebot, María Victoria
dc.date.issued
2020-10-07T11:06:55Z
dc.date.issued
2021-09-22T05:10:23Z
dc.date.issued
2020-09-22
dc.date.issued
2020-10-07T11:06:56Z
dc.identifier
https://hdl.handle.net/2445/171020
dc.description.abstract
On-line solid-phase extraction capillary electrophoresis-mass spectrometry (SPE-CE-MS) is a powerful technique for high throughput sample clean-up and analyte preconcentration, separation, detection, and characterization. The most typical design due to its simplicity and low cost is unidirectional SPE-CE-MS. However, in this configuration, the sample volumes introduced by pressure depend on the dimensions of the separation capillary and some matrix components could be irreversibly adsorbed in its inner walls. Furthermore, in many cases, the requirements of on-line preconcentration are incompatible with the background electrolyte necessary for an efficient separation and sensitive MS detection. Here, we present SPE-CE-MS with a nanoliter valve (nvSPE-CE-MS) to overcome these drawbacks while keeping the design simple. The nvSPE-CE-MS system is operated with a single CE instrument and two capillaries for independent and orthogonal SPE preconcentration and CE separation, which are interfaced through an external and electrically isolated valve with a 20 nL sample loop. The instrumental setup is proved for the analysis of opioid and amyloid beta peptide biomarkers in standards and plasma samples. NvSPE-CE-MS allowed decreasing the limits of detection (LODs) 200 times with regard to CE-MS. Compared to unidirectional SPE-CE-MS, peak efficiencies were better and repeatabilities similar, but total analysis times longer and LODs for standards slightly higher due to the heart-cut operation and the limited volume of the valve loop. This small difference on the LODs for standards was compensated for plasma samples by the improved tolerance of nvSPE-CE-MS to complex sample matrices. In view of these results, the presented setup can be regarded as a promising versatile alternative to avoid complicated matrix samples entering the separation capillary in SPE-CE-MS.
dc.format
application/pdf
dc.publisher
Elsevier B.V.
dc.relation
Versió postprint del document publicat a: https://doi.org/10.1016/j.aca.2020.09.036
dc.relation
Analytica Chimica Acta, 2020, vol. 1140, p. 1-9
dc.relation
https://doi.org/10.1016/j.aca.2020.09.036
dc.rights
cc-by-nc-nd (c) Elsevier B.V., 2020
dc.rights
http://creativecommons.org/licenses/by-nc-nd/3.0/es
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject
Electroforesi capil·lar
dc.subject
Espectrometria de masses
dc.subject
Capillary electrophoresis
dc.subject
Mass spectrometry
dc.title
Evaluation of on-line solid-phase extraction capillary electrophoresis-mass spectrometry with a nanoliter valve for the analysis of peptide biomarkers
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/acceptedVersion