dc.contributor.author
Vásconez, Jeanneth
dc.contributor.author
Peró Gascón, Roger
dc.contributor.author
Giménez López, Estela
dc.contributor.author
Benavente Moreno, Fernando J. (Julián)
dc.date.issued
2020-09-18T09:43:03Z
dc.date.issued
2022-06-16T05:10:20Z
dc.date.issued
2020-06-16
dc.date.issued
2020-09-18T09:43:03Z
dc.identifier
https://hdl.handle.net/2445/170729
dc.description.abstract
This study evaluates zwitterionic-hydrophilic interaction capillary liquid chromatography (capZIC-HILIC) and capillary electrophoresis (CE) with ultraviolet (UV) and mass spectrometry (MS) detection for the direct, label-free and multiplex analysis of microribonucleic acids (miRNAs). CapZIC-HILIC-UV and CE-UV methods were first optimized, resulting in similar separations for a mixture of three miRNAs (hsa-iso-miR-16-5p, hsa-let-7g-5p, and hsa-miR-21-5p) but with reversal of elution/migration orders and small differences in repeatability, linearity, limit of detection (LOD) and separation efficiency. The established UV methods were transferred and validated in these terms with mass spectrometry (MS) detection, which allowed identifying the miRNAs and characterizing their post-transcriptional modifications. LOD by capZIC-HILIC-MS was 1 µM of miRNA, around 5 times lower than by CE-MS due to the analyte dilution with the sheathflow CE-MS interface and to the slightly increased abundance of alkali metals adducts in the CE-MS mass spectra. In addition, the suction effect promoted by the nebulizer gas in CE-MS negatively affected the already compromised separations. In contrast, CE-MS showed superior repeatabilities with spiked serum samples, as well as reduced costs, extended capillary column durabilities and shorter conditioning times. The comparison of the different methods allows disclosing the current advantages and disadvantages of capZIC-HILIC and CE for the analysis of miRNA biomarkers.
dc.format
application/pdf
dc.format
application/pdf
dc.publisher
Elsevier B.V.
dc.relation
Versió postprint del document publicat a: https://doi.org/10.1016/j.talanta.2020.121263
dc.relation
Talanta, 2020, vol. 219, p. 121263
dc.relation
https://doi.org/10.1016/j.talanta.2020.121263
dc.rights
cc-by-nc-nd (c) Elsevier B.V., 2020
dc.rights
http://creativecommons.org/licenses/by-nc-nd/3.0/es
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject
Electroforesi capil·lar
dc.subject
Marcadors bioquímics
dc.subject
Espectrometria de masses
dc.subject
Capillary electrophoresis
dc.subject
Biochemical markers
dc.subject
Mass spectrometry
dc.title
Comparison of capillary electrophoresis and zwitterionic-hydrophilic interaction capillary liquid chromatography with ultraviolet and mass spectrometry detection for the analysis of microRNA biomarkers
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/acceptedVersion