An Instantaneous low-cost point-of-care anemia detection device

dc.contributor.author
Punter Villagrasa, Jaime
dc.contributor.author
Cid Vidal, Joan
dc.contributor.author
Páez Avilés, Cristina
dc.contributor.author
Rodríguez-Villarreal, Ivón
dc.contributor.author
Juanola, Esteve
dc.contributor.author
Colomer i Farrarons, Jordi
dc.contributor.author
Miribel-Català, Pere Ll. (Pere Lluís)
dc.date.issued
2020-03-10T11:02:42Z
dc.date.issued
2020-03-10T11:02:42Z
dc.date.issued
2015-02-16
dc.date.issued
2020-03-10T11:02:42Z
dc.identifier
1424-8220
dc.identifier
https://hdl.handle.net/2445/152311
dc.identifier
649191
dc.identifier
25690552
dc.description.abstract
We present a small, compact and portable device for point-of-care instantaneous early detection of anemia. The method used is based on direct hematocrit measurement from whole blood samples by means of impedance analysis. This device consists of a custom electronic instrumentation and a plug-and-play disposable sensor. The designed electronics rely on straightforward standards for low power consumption, resulting in a robust and low consumption device making it completely mobile with a long battery life. Another approach could be powering the system based on other solutions like indoor solar cells, or applying energy-harvesting solutions in order to remove the batteries. The sensing system is based on a disposable low-cost label-free three gold electrode commercial sensor for 50 µL blood samples. The device capability for anemia detection has been validated through 24 blood samples, obtained from four hospitalized patients at Hospital Clínic. As a result, the response, effectiveness and robustness of the portable point-of-care device to detect anemia has been proved with an accuracy error of 2.83% and a mean coefficient of variation of 2.57% without any particular case above 5%.
dc.format
14 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
MDPI
dc.relation
Reproducció del document publicat a: https://doi.org/10.3390/s150204564
dc.relation
Sensors, 2015, vol. 15, num. 2, p. 4564-4577
dc.relation
https://doi.org/10.3390/s150204564
dc.rights
cc-by (c) Punter Villagrasa, Jaime et al., 2015
dc.rights
http://creativecommons.org/licenses/by/3.0/es
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Enginyeria Electrònica i Biomèdica)
dc.subject
Espectroscòpia d'impedància
dc.subject
Sang
dc.subject
Electrònica
dc.subject
Impedance spectroscopy
dc.subject
Blood
dc.subject
Electronics
dc.title
An Instantaneous low-cost point-of-care anemia detection device
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)