Comparison of 2D versus M-mode echocardiography for assessing fetal myocardial wall thickness

dc.contributor.author
Sepúlveda Martínez, Álvaro
dc.contributor.author
García-Otero, Laura
dc.contributor.author
Soveral, Iris
dc.contributor.author
Guirado, Laura
dc.contributor.author
Valenzuela Alcaraz, Brenda I.
dc.contributor.author
Torres, Ximena
dc.contributor.author
Rodríguez López, Mérida
dc.contributor.author
Gratacós Solsona, Eduard
dc.contributor.author
Gómez, Olga
dc.contributor.author
Crispi Brillas, Fàtima
dc.date.issued
2019-11-21T11:05:26Z
dc.date.issued
2019-11-21T11:05:26Z
dc.date.issued
2018-02-11
dc.date.issued
2019-11-21T11:05:26Z
dc.identifier
1476-7058
dc.identifier
https://hdl.handle.net/2445/145218
dc.identifier
678938
dc.description.abstract
OBJECTIVE: M-mode and 2D have been proposed for evaluating fetal myocardial thickness. However, studies comparing the performance of both modalities are lacking. We aimed to compare 2D versus M-mode reproducibility for assessing myocardial wall thicknesses. METHODS: A prospective study including 45 healthy fetuses from low-risk pregnancies evaluated between 18 and 41 weeks of gestation. Left and right ventricular free-wall and septal myocardial thicknesses were measured at end-diastole (ED) and end-systole (ES) in transverse 4-chamber view using 2D and M-mode. Intra- and interobserver reproducibility was evaluated by the concordance correlation coefficient (CCC). Both techniques were compared by t-test of the CCC. RESULTS: 2D and M-mode demonstrated excellent and similar intraobserver repeatability, with the best concordance in ES septal thickness (M-mode CCC 0.956 versus 2D-mode CCC 0.914). Interobserver reproducibility demonstrated also a high concordance, optimal in ES left ventricular free wall (M-mode 0.925 versus 2 D 0.855). Comparison of both techniques demonstrated a high concordance in all measurements, except for ED septal thickness with better reproducibility using M-mode (CCC 0.954 versus 0.847, p = .017). CONCLUSIONS: 2D and M-mode can be used in a reproducible manner for measuring fetal myocardial thickness, with a slightly better performance of M-mode for assessing ED septal wall thickness.
dc.format
24 p.
dc.format
application/pdf
dc.format
application/pdf
dc.language
eng
dc.publisher
Informa UK Ltd.
dc.relation
Versió postprint del document publicat a: https://doi.org/10.1080/14767058.2018.1432041
dc.relation
Journal Of Maternal-Fetal & Neonatal Medicine, 2018, vol. 32, num. 14, p. 2319-2327
dc.relation
https://doi.org/10.1080/14767058.2018.1432041
dc.rights
(c) Informa UK Ltd., 2018
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)
dc.subject
Ecocardiografia
dc.subject
Cor
dc.subject
Fetus
dc.subject
Estudi de casos
dc.subject
Echocardiography
dc.subject
Heart
dc.subject
Fetus
dc.subject
Case studies
dc.title
Comparison of 2D versus M-mode echocardiography for assessing fetal myocardial wall thickness
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/acceptedVersion


Files in this item

FilesSizeFormatView

There are no files associated with this item.