Evaluation of the MagicplexTM sepsis real-time test for the rapid diagnosis of bloodstream infections in adults

dc.contributor.author
Zboromyrska, Yuliya
dc.contributor.author
Cillóniz, Catia
dc.contributor.author
Cobos-Trigueros, Nazaret
dc.contributor.author
Almela, M. (Manel)
dc.contributor.author
Hurtado, Juan Carlos
dc.contributor.author
Vergara Gómez, Andrea
dc.contributor.author
Mata, Caterina
dc.contributor.author
Soriano Viladomiu, Alex
dc.contributor.author
Mensa Pueyo, Josep
dc.contributor.author
Marco Reverté, Francesc
dc.contributor.author
Vila Estapé, Jordi
dc.date.issued
2019-06-20T13:40:49Z
dc.date.issued
2019-06-20T13:40:49Z
dc.date.issued
2019-03-12
dc.date.issued
2019-06-20T13:40:50Z
dc.identifier
2235-2988
dc.identifier
https://hdl.handle.net/2445/135677
dc.identifier
689353
dc.identifier
30931259
dc.description.abstract
Sepsis is a serious health condition worldwide, affecting more than 30 million people globally each year. Blood culture (BC) is generally used to diagnose sepsis because of the low quantity of microbes occurring in the blood during such infections. However, ~50% of bloodstream infections (BSI) give negative BC, this figure being higher for sepsis, which delays the start of appropriate antimicrobial therapy. This prospective study evaluated a multiplex real-time polymerase chain reaction, the MagicplexTM Sepsis test (MP), for the detection of pathogens from whole blood, comparing it to routine BC. We analyzed 809 blood samples from 636 adult patients, with 132/809 (16.3%) of the samples positive for one or more relevant microorganism according to BC and/or MP. The sensitivity and specificity of MP were 29 and 95%, respectively, while the level of agreement between BC and MP was 87%. The rate of contaminated samples was higher for BC (10%) than MP (4.8%) (P < 0.001). Patients with only MP-positive samples were more likely to be on antimicrobial treatment (47%) than those with only BC-positive samples (18%) (P = 0.002). In summary, the MP test could be useful in some clinical setting, such as among patients on antibiotic therapy. Nevertheless, a low sensitivity demonstrated impairs its use as a part of a routine diagnostic algorithm.
dc.format
8 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
Frontiers Media
dc.relation
Reproducció del document publicat a: https://doi.org/10.3389/fcimb.2019.00056
dc.relation
Frontiers in Cellular and Infection Microbiology, 2019, vol. 9, p. 56
dc.relation
https://doi.org/10.3389/fcimb.2019.00056
dc.rights
cc-by (c) Zboromyrska,Yuliya et al., 2019
dc.rights
http://creativecommons.org/licenses/by/3.0/es
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Fonaments Clínics)
dc.subject
Septicèmia
dc.subject
Cultius (Biologia)
dc.subject
Sang
dc.subject
Infeccions
dc.subject
Septicemia
dc.subject
Cultures (Biology)
dc.subject
Blood
dc.subject
Infections
dc.title
Evaluation of the MagicplexTM sepsis real-time test for the rapid diagnosis of bloodstream infections in adults