Impact of Region-of-Interest Delineation Methods, Reconstruction Algorithms, and Intra- and Inter-Operator Variability on Internal Dosimetry Estimates Using PET

dc.contributor.author
López Vilanova, N.
dc.contributor.author
Pavía Segura, Javier
dc.contributor.author
Duch Guillén, Ma. Amor (María Amor)
dc.contributor.author
Catafau Alcántara, Ana Ma.
dc.contributor.author
Ros Puig, Domènec
dc.contributor.author
Bullich Roig, Santiago
dc.date.issued
2019-02-05T14:25:28Z
dc.date.issued
2019-02-05T14:25:28Z
dc.date.issued
2017-04-01
dc.date.issued
2019-02-05T14:25:28Z
dc.identifier
1536-1632
dc.identifier
https://hdl.handle.net/2445/127920
dc.identifier
676540
dc.identifier
27632424
dc.description.abstract
Purpose: Human dosimetry studies play a central role in radioligand development for positron emission tomography (PET). Drawing regions of interest (ROIs) on the PET images is used to measure the dose in each organ. In the study aspects related to ROI delineation methods were evaluated for two radioligands of different biodistribution (intestinal vs urinary). Procedures: PET images were simulated from a human voxel-based phantom. Several ROI delineation methods were tested: antero-posterior projections (AP), 3D sub-samples of the organs (S), and a 3D volume covering the whole-organ (W). Inter- and intra-operator variability ROI drawing was evaluated by using human data. Results: The effective dose estimates using S and W methods were comparable to the true values. AP methods overestimated (49 %) the dose for the radioligand with intestinal biodistribution. Moreover, the AP method showed the highest inter-operator variability: 11 ± 1 %. Conclusions: The sub-sampled organ method showed the best balance between quantitative accuracy and inter- and intra-operator variability.
dc.format
10 p.
dc.format
application/pdf
dc.format
application/pdf
dc.language
eng
dc.publisher
Springer Verlag
dc.relation
Versió postprint del document publicat a: https://doi.org/10.1007/s11307-016-1003-4
dc.relation
Molecular Imaging and Biology, 2017, vol. 19, num. 2, p. 305-314
dc.relation
https://doi.org/10.1007/s11307-016-1003-4
dc.rights
(c) Academy of Molecular Imaging; European Society for Molecular Imaging; Society for Molecular Imaging, 2017
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Fonaments Clínics)
dc.subject
Dosimetria (Radiació)
dc.subject
Radiation dosimetry
dc.title
Impact of Region-of-Interest Delineation Methods, Reconstruction Algorithms, and Intra- and Inter-Operator Variability on Internal Dosimetry Estimates Using PET
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/acceptedVersion


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.