Selenocystine modified screen-printed electrode as an alternative sensor for the voltammetric determination of metal ions

dc.contributor.author
Puy, Jaume
dc.contributor.author
Pérez Ràfols, Clara
dc.contributor.author
Serrano i Plana, Núria
dc.contributor.author
Díaz Cruz, José Manuel
dc.contributor.author
Ariño Blasco, Cristina
dc.contributor.author
Esteban i Cortada, Miquel
dc.date.issued
2019-01-29T18:08:12Z
dc.date.issued
2019-07-29T05:10:18Z
dc.date.issued
2017-07-29
dc.date.issued
2019-01-29T18:08:12Z
dc.identifier
0039-9140
dc.identifier
https://hdl.handle.net/2445/127716
dc.identifier
673186
dc.identifier
28842024
dc.description.abstract
A novel selenium based screen-printed electrode was developed based on the immobilization of selenocystine on aryl diazonium salt monolayers anchored to a carbon-nanofiber screen-printed electrode support (SeCyst- SPCNFE). SeCyst-SPCNFE was analytically compared to a screen-printed carbon nanofiber electrode modified with L-Cystine (Cyst-SPCNFE) for the determination of Pb(II) and Cd(II) by stripping voltammetric techniques. Their analytical performance suggests that SeCyst-SPCNFE could be a much better alternative for metal ion determination at trace levels than Cyst-SPCNFE. The proposed electrode was successfully applied for the simultaneous voltammetric determination of trace Pb(II) and Cd(II) in a wastewater reference material with a very high reproducibility (3.2%) and good trueness (2.6%).
dc.format
6 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
Elsevier B.V.
dc.relation
Versió postprint del document publicat a: https://doi.org/10.1016/j.talanta.2017.07.089
dc.relation
Talanta, 2017, vol. 175, p. 501-506
dc.relation
https://doi.org/10.1016/j.talanta.2017.07.089
dc.rights
cc-by-nc-nd (c) Elsevier B.V., 2017
dc.rights
http://creativecommons.org/licenses/by-nc-nd/3.0/es
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject
Voltametria
dc.subject
Elèctrodes
dc.subject
Seleni
dc.subject
Voltammetry
dc.subject
Electrodes
dc.subject
Selenium
dc.title
Selenocystine modified screen-printed electrode as an alternative sensor for the voltammetric determination of metal ions
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/acceptedVersion


Fitxers en aquest element

FitxersGrandàriaFormatVisualització

No hi ha fitxers associats a aquest element.

Aquest element apareix en la col·lecció o col·leccions següent(s)