Simultaneous determination of Tl(I) and In(III) using a voltammetric sensor array

dc.contributor.author
Pérez Ràfols, Clara
dc.contributor.author
Serrano i Plana, Núria
dc.contributor.author
Díaz Cruz, José Manuel
dc.contributor.author
Ariño Blasco, Cristina
dc.contributor.author
Esteban i Cortada, Miquel
dc.date.issued
2018-10-24T12:29:26Z
dc.date.issued
2019-01-17T06:10:21Z
dc.date.issued
2017-01-17
dc.date.issued
2018-10-24T12:29:26Z
dc.identifier
0925-4005
dc.identifier
https://hdl.handle.net/2445/125592
dc.identifier
667226
dc.description.abstract
A sensor array consisting of a chemically modified sensor in which 4-carboxybenzo-18-crown-6 was immobilized onto a screen-printed carbon nanofiber-modified electrode (crown-6-SPCNFE) and an ex-situ antimony film deposited on a screen-printed carbon nanofiber-modified electrode (ex-situ-SbSPCNFE) was applied for the resolution of the strong overlapped signals resulting from the simultaneous determination of Tl(I) and In(III) by stripping voltammetry. A Partial Least Squares model was constructed and good calibration curves of predicted vs. expected concentrations of the considered metal ions, with correlation coefficients higher than 0.98 for both training and test sets, were obtained. These results provided by the sensor array were compared with those obtained by a single electrode. Moreover, this sensor array was successfully applied for the voltammetric determination of both Tl(I) and In(III) in tap water, providing comparable results to those obtained by ICP-MS measurements.
dc.format
31 p.
dc.format
application/pdf
dc.format
application/pdf
dc.language
eng
dc.publisher
Elsevier B.V.
dc.relation
Versió postprint del document publicat a: https://doi.org/10.1016/j.snb.2017.01.089
dc.relation
Sensors and Actuators B-Chemical, 2017, vol. 245, p. 18-24
dc.relation
https://doi.org/10.1016/j.snb.2017.01.089
dc.rights
cc-by-nc-nd (c) Elsevier B.V., 2017
dc.rights
http://creativecommons.org/licenses/by-nc-nd/3.0/es
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject
Ions metàl·lics
dc.subject
Voltametria
dc.subject
Anàlisi electroquímica
dc.subject
Metal ions
dc.subject
Voltammetry
dc.subject
Electrochemical analysis
dc.title
Simultaneous determination of Tl(I) and In(III) using a voltammetric sensor array
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/acceptedVersion


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)