Determination of acidity constants and prediction of electrophoretic separation of amyloid beta peptides

dc.contributor.author
Peró Gascón, Roger
dc.contributor.author
Benavente Moreno, Fernando J. (Julián)
dc.contributor.author
Barbosa Torralbo, José
dc.contributor.author
Sanz Nebot, María Victoria
dc.date.issued
2018-06-21T14:36:06Z
dc.date.issued
2019-05-31T05:10:17Z
dc.date.issued
2017-05-31
dc.date.issued
2018-06-21T14:36:06Z
dc.identifier
0021-9673
dc.identifier
https://hdl.handle.net/2445/123189
dc.identifier
664231
dc.identifier
28619586
dc.description.abstract
In this paper we describe a strategy to estimate by CE the acidity constants (pKa) of complex polyprotic peptides from their building peptide fragments. CE has been used for the determination of the pKas of five short polyprotic peptides that cover all the sequence of amyloid beta (Aβ) peptides 1-40 and 1-42 (Aβ fragments 1-15, 10-20, 20-29, 25-35 and 33-42). First, the electrophoretic mobility (me) was measured as a function of pH of the background electrolyte (BGE) in the pH range 2-12 (bare fused silica capillary, I=25mM and T=25ºC). Second, the mes were fitted to equations modelling the ionisable behaviour of the different fragments as a function of pH to determine their pKas. The accuracy of the pKas was demonstrated predicting the electrophoretic behaviour of the studied fragments using the classical semiempirical relationships between me and peptide charge-to-mass ratio (me vs. q/Mr1/2, classical polymer model, q=charge and Mr=relative molecular mass). Separation selectivity in a mixture of the fragments as a function of pH was evaluated, taking into account the influence of the EOF at each pH value, and a method for the simple and rapid simulation of the electropherograms at the optimum separation pH was described. Finally, the pKas of the fragments were used to estimate the pKas of the Aβ peptides 1-40 and 1-42 (tC and D 3.1, E 4.6 and Y 10.8 for acidic amino acids and tN-D 8.6, H 6.0, K 10.6 and R 12.5 for basic amino acids), which were used to predict their behaviour and simulate their electropherograms with excellent results. However, as expected due to the very small differences on q/Mr1/2 values, separation resolution of their mixtures was poor over the whole pH range. The use of poly(vinyl alcohol) (PVA) coated capillaries allowed reducing the electroosmotic flow (EOF) and a slight improvement of resolution.
dc.format
10 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
Elsevier B.V.
dc.relation
Versió postprint del document publicat a: https://doi.org/10.1016/j.chroma.2017.05.069
dc.relation
Journal of Chromatography A, 2017, vol. 1508, p. 148-157
dc.relation
https://doi.org/10.1016/j.chroma.2017.05.069
dc.rights
cc-by-nc-nd (c) Elsevier B.V., 2017
dc.rights
http://creativecommons.org/licenses/by-nc-nd/3.0/es
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject
Amiloïdosi
dc.subject
Pèptids
dc.subject
Electroforesi capil·lar
dc.subject
Dissociació (Química)
dc.subject
Amyloidosis
dc.subject
Peptides
dc.subject
Capillary electrophoresis
dc.subject
Dissociation
dc.title
Determination of acidity constants and prediction of electrophoretic separation of amyloid beta peptides
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/acceptedVersion


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)