Validity of the Polar V800 monitor for measuring heart rate variability in mountain running route conditions

dc.contributor.author
Caminal Magrans, Pere
dc.contributor.author
Sola, Fuensanta
dc.contributor.author
Gomis, Pedro
dc.contributor.author
Guasch i Casany, Eduard
dc.contributor.author
Perera Lluna, Alexandre
dc.contributor.author
Soriano, Núria
dc.contributor.author
Mont Girbau, Lluís
dc.date.issued
2018-04-27T15:21:56Z
dc.date.issued
2019-01-22T06:10:18Z
dc.date.issued
2018-01-22
dc.date.issued
2018-04-27T15:21:56Z
dc.identifier
1439-6319
dc.identifier
https://hdl.handle.net/2445/121933
dc.identifier
675813
dc.identifier
29356949
dc.description.abstract
PURPOSE: This study was conducted to test, in mountain running route conditions, the accuracy of the Polar V800 monitor as a suitable device for monitoring the heart rate variability (HRV) of runners. METHOD: Eighteen healthy subjects ran a route that included a range of running slopes such as those encountered in trail and ultra-trail races. The comparative study of a V800 and a Holter SEER 12 ECG Recorder included the analysis of RR time series and short-term HRV analysis. A correction algorithm was designed to obtain the corrected Polar RR intervals. Six 5-min segments related to different running slopes were considered for each subject. RESULTS: The correlation between corrected V800 RR intervals and Holter RR intervals was very high (r = 0.99, p < 0.001), and the bias was less than 1 ms. The limits of agreement (LoA) obtained for SDNN and RMSSD were (- 0.25 to 0.32 ms) and (- 0.90 to 1.08 ms), respectively. The effect size (ES) obtained in the time domain HRV parameters was considered small (ES < 0.2). Frequency domain HRV parameters did not differ (p > 0.05) and were well correlated (r ≥ 0.96, p < 0.001). CONCLUSION: Narrow limits of agreement, high correlations and small effect size suggest that the Polar V800 is a valid tool for the analysis of heart rate variability in athletes while running high endurance events such as marathon, trail, and ultra-trail races. KEYWORDS: HRV; Open field running conditions; Polar V800 heart rate monitor; Validation
dc.format
14 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
Springer Verlag
dc.relation
Versió postprint del document publicat a: https://doi.org/10.1007/s00421-018-3808-0
dc.relation
European Journal of Applied Physiology, 2018, vol. 118, num. 3, p. 669-677
dc.relation
https://doi.org/10.1007/s00421-018-3808-0
dc.relation
info:eu-repo/grantAgreement/EC/H2020/633196/EU//CATCH ME
dc.rights
(c) Springer Verlag, 2018
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Medicina)
dc.subject
Batecs cardíacs
dc.subject
Monitoratge de pacients
dc.subject
Exercici
dc.subject
Proves d'esforç
dc.subject
Heart beat
dc.subject
Patient monitoring
dc.subject
Exercise
dc.subject
Exercise tests
dc.title
Validity of the Polar V800 monitor for measuring heart rate variability in mountain running route conditions
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/acceptedVersion


Files in this item

FilesSizeFormatView

There are no files associated with this item.