Cryostat slice irregularities may introduce bias in tissue thickness estimation: relevance for cell counting methods

dc.contributor.author
Puigdellívol Sánchez, Anna
dc.contributor.author
Giralt Torroella, Albert
dc.contributor.author
Casanovas, Anna
dc.contributor.author
Alberch i Vié, Jordi, 1959-
dc.contributor.author
Prats Galino, Alberto
dc.date.issued
2016-09-02T11:58:08Z
dc.date.issued
2016-09-02T11:58:08Z
dc.date.issued
2015-07-15
dc.date.issued
2016-09-02T11:58:14Z
dc.identifier
1431-9276
dc.identifier
https://hdl.handle.net/2445/101504
dc.identifier
654611
dc.identifier
26173483
dc.description.abstract
Stereological techniques using the optical disectors require estimation of final section thickness, but frozen tissue irregularities may interfere with this estimation. Cryostat slices from rodent nerve tissues (dorsal root ganglia, spinal cord, and brain), cut at 16, 40, and 50 μm, were digitized with a confocal microscope and visualized through 3D software. Geometric section thickness of tissue (Tgeom) was defined as tissue volume/area. Maximal section thicknesses (Tmax), from the top to the bottom of the section, were measured in a random sample of vertical ZX planes. Irregularities were mostly related to blood vessels traversing the tissue and neuronal somas protruding over the cut surfaces, with other neuron profiles showing a fragmented appearance. Irregularities contributed to increasing the distance between the tops and bottoms of slices sectioned in different laboratories. Significant differences were found between Tmax and Tgeom for all thickness studies and counting frames (p<0.01). The Tgeom/Tmax average rate was 68.4 85.7% in volumes around cell profiles (∼600 1,200 μm2) and 83.3 91.8% in subcellular samples (∼25 160 μm2). Confocal microscopy may help to assess tissue irregularities, which might lead to an overestimation of tissue volume if section thickness is estimated by focusing on the top and bottom of the sections.
dc.format
9 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
Cambridge University Press
dc.relation
Reproducció del document publicat a: http://dx.doi.org/10.1017/S143192761501380X
dc.relation
Microscopy and Microanalysis, 2015, vol. 21, num. 4
dc.relation
http://dx.doi.org/10.1017/S143192761501380X
dc.rights
(c) Cambridge University Press, 2015
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)
dc.subject
Microscòpia mèdica
dc.subject
Cèl·lules
dc.subject
Visualització tridimensional
dc.subject
Medical microscopy
dc.subject
Cells
dc.subject
Three-dimensional display systems
dc.title
Cryostat slice irregularities may introduce bias in tissue thickness estimation: relevance for cell counting methods
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Fitxers en aquest element

FitxersGrandàriaFormatVisualització

No hi ha fitxers associats a aquest element.

Aquest element apareix en la col·lecció o col·leccions següent(s)