Improved Framework for Tractography Reconstruction of the Optic Radiation

dc.contributor.author
Martinez-Heras, Eloy
dc.contributor.author
Varriano, Federico
dc.contributor.author
Prčkovska, Vesna
dc.contributor.author
Laredo, Carlos
dc.contributor.author
Andorra, Magi
dc.contributor.author
Martínez Lapiscina, Elena H.
dc.contributor.author
Calvo, Anna
dc.contributor.author
Lampert, Erika
dc.contributor.author
Villoslada, Pablo
dc.contributor.author
Saiz Hinarejos, Albert
dc.contributor.author
Prats Galino, Alberto
dc.contributor.author
Llufriu Duran, Sara
dc.date.issued
2016-07-13T07:03:49Z
dc.date.issued
2016-07-13T07:03:49Z
dc.date.issued
2015-09-16
dc.date.issued
2016-07-13T07:03:54Z
dc.identifier
1932-6203
dc.identifier
https://hdl.handle.net/2445/100420
dc.identifier
657642
dc.identifier
26376179
dc.description.abstract
The optic radiation (OR) is one of the major components of the visual system and a key structure at risk in white matter diseases such as multiple sclerosis (MS). However, it is challenging to perform track reconstruction of the OR using diffusion MRI due to a sharp change of direction in the Meyer's loop and the presence of kissing and crossing fibers along the pathway. As such, we aimed to provide a highly precise and reproducible framework for tracking the OR from thalamic and visual cortex masks. The framework combined the generation of probabilistic streamlines by high order fiber orientation distributions estimated with constrained spherical deconvolution and an automatic post-processing based on anatomical exclusion criteria (AEC) to compensate for the presence of anatomically implausible streamlines. Specifically, those ending in the contralateral hemisphere, cerebrospinal fluid or grey matter outside the visual cortex were automatically excluded. We applied the framework to two distinct high angular resolution diffusion-weighted imaging (HARDI) acquisition protocols on one cohort, comprised of ten healthy volunteers and five MS patients. The OR was successfully delineated in both HARDI acquisitions in the healthy volunteers and MS patients. Quantitative evaluation of the OR position was done by comparing the results with histological reference data. Compared with histological mask, the OR reconstruction into a template (OR-TCT) was highly precise (percentage of voxels within the OR-TCT correctly defined as OR), ranging from 0.71 to 0.83. The sensitivity (percentage of voxels in histological reference mask correctly defined as OR in OR-TCT) ranged from 0.65 to 0.81 and the accuracy (measured by F1 score) was 0.73 to 0.77 in healthy volunteers. When AEC was not applied the precision and accuracy decreased. The absolute agreement between both HARDI datasets measured by the intraclass correlation coefficient was 0.73. This improved framework allowed us to reconstruct the OR with high reliability and accuracy independently of the acquisition parameters. Moreover, the reconstruction was possible even in the presence of tissue damage due to MS. This framework could also be applied to other tracts with complex configuration.
dc.format
16 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
Public Library of Science (PLoS)
dc.relation
Reproducció del document publicat a: http://dx.doi.org/10.1371/journal.pone.0137064
dc.relation
PLoS One, 2015, vol. 10, num. 9
dc.relation
http://dx.doi.org/10.1371/journal.pone.0137064
dc.relation
info:eu-repo/grantAgreement/EC/FP7/328060/EU//CONNECTMS
dc.rights
cc-by (c) Martinez-Heras, Eloy et al., 2015
dc.rights
http://creativecommons.org/licenses/by/3.0/es
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)
dc.subject
Còrtex visual
dc.subject
Histologia
dc.subject
Esclerosi múltiple
dc.subject
Ressonància magnètica
dc.subject
Estudi de casos
dc.subject
Patologia
dc.subject
Visualització tridimensional
dc.subject
Visual cortex
dc.subject
Histology
dc.subject
Multiple sclerosis
dc.subject
Magnetic resonance
dc.subject
Case studies
dc.subject
Pathology
dc.subject
Three-dimensional display systems
dc.title
Improved Framework for Tractography Reconstruction of the Optic Radiation
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Files in this item

FilesSizeFormatView

There are no files associated with this item.