Shear wave cardiovascular MR elastography using intrinsic cardiac motion for transducer-free non-invasive evaluation of myocardial shear wave velocity

dc.contributor
Universitat Ramon Llull. IQS
dc.contributor.author
Martorell López, Jordi
dc.contributor.author
Polcaro, Alessandro
dc.contributor.author
Troelstra, Marian Amber
dc.contributor.author
Runge, Jurgen Henk
dc.contributor.author
Burnhope, Emma
dc.contributor.author
Guenthner, Christian
dc.contributor.author
Schneider, Torben
dc.contributor.author
Razavi, Reza
dc.contributor.author
Ismail, Tevfik F.
dc.contributor.author
Sinkus, Ralph
dc.date.accessioned
2025-05-14T11:41:55Z
dc.date.available
2025-05-14T11:41:55Z
dc.date.issued
2021-01
dc.identifier.uri
http://hdl.handle.net/20.500.14342/972
dc.description.abstract
Changes in myocardial stiffness may represent a valuable biomarker for early tissue injury or adverse remodeling. In this study, we developed and validated a novel transducer-free magnetic resonance elastography (MRE) approach for quantifying myocardial biomechanics using aortic valve closure-induced shear waves. Using motion-sensitized two-dimensional pencil beams, septal shear waves were imaged at high temporal resolution. Shear wave speed was measured using time-of-flight of waves travelling between two pencil beams and corrected for geometrical biases. After validation in phantoms, results from twelve healthy volunteers and five cardiac patients (two left ventricular hypertrophy, two myocardial infarcts, and one without confirmed pathology) were obtained. Torsional shear wave speed in the phantom was 3.0 ± 0.1 m/s, corresponding with reference speeds of 2.8 ± 0.1 m/s. Geometrically-biased flexural shear wave speed was 1.9 ± 0.1 m/s, corresponding with simulation values of 2.0 m/s. Corrected septal shear wave speeds were significantly higher in patients than healthy volunteers [14.1 (11.0–15.8) m/s versus 3.6 (2.7–4.3) m/s, p = 0.001]. The interobserver 95%-limits-of-agreement in healthy volunteers were ± 1.3 m/s and interstudy 95%-limits-of-agreement − 0.7 to 1.2 m/s. In conclusion, myocardial shear wave speed can be measured using aortic valve closure-induced shear waves, with cardiac patients showing significantly higher shear wave speeds than healthy volunteers. This non-invasive measure may provide valuable insights into the pathophysiology of heart failure.
dc.format.extent
14 p.
dc.language.iso
eng
dc.publisher
Nature Research
dc.relation.ispartof
Scientific Reports. Vol.11, 1403 (2021)
dc.rights
Attribution 4.0 International
dc.rights
© L'autor/a
dc.rights.uri
http://creativecommons.org/licenses/by/4.0/
dc.subject
Cardiologia
dc.subject
Miocardi
dc.subject
Transductors
dc.subject
Cardiology
dc.subject
Cardiovascular diseases
dc.subject
Magnetic resonance imaging
dc.subject
Translational research
dc.title
Shear wave cardiovascular MR elastography using intrinsic cardiac motion for transducer-free non-invasive evaluation of myocardial shear wave velocity
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion
dc.subject.udc
616.1
dc.embargo.terms
cap
dc.relation.projectID
info:eu-repo/grantAgreement/EU/H2020/Grant No. 668039
dc.identifier.doi
https://doi.org/10.1038/s41598-020-79231-z
dc.rights.accessLevel
info:eu-repo/semantics/openAccess


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

IQS [794]