dc.description.abstract
BACKGROUND
Compared with other methods, the stationary liquid mass balance method for oxygen uptake rate (OUR) determination offers advantages in terms of estimation accuracy and reduction of stress. However, the need for sophisticated instrumentation, like mass flow controllers and gas analysers, has historically limited wider implementation of such a method. In this paper, a new simplified method based on inexpensive valves for the continuous estimation of OUR in animal cell cultures is evaluated. The determination of OUR values is based on accurate operation of the dissolved oxygen (DO) control loop and monitoring of its internal variables.
RESULTS
The method developed was tested empirically in 2 L bioreactor HEK293 batch cultures. OUR profiles obtained by a dynamic method, global mass balance method and the developed simplified method were monitored and compared. The results show how OUR profile obtained with the proposed method better follows the off-line cell density determination. The OUR estimation frequency was also increased, improving the method capabilities and applications. The theoretical rationale of the method was extended to the sensitivity analysis which was analytically and numerically approached.
CONCLUSIONS
The results showed the proposed method to be not only cheap, but also a reliable alternative to monitor the metabolic activity in bioreactors in many biotechnological processes, being a useful tool for high cell density culture strategies implementation based on OUR monitoring.
dc.publisher
John Wiley & Sons
dc.relation.ispartof
Journal of Chemical Technology and Biotechnology. Vol.93, n.6 (2018), p.1757-1766
dc.rights
© Society of Chemical Industry. Tots els drets reservats
dc.subject
On-line monitoring
dc.subject
Dissolved oxygen control
dc.subject
Liquid mass balance
dc.title
A simplified implementation of the stationary liquid mass balance method for on‐line OUR monitoring in animal cell cultures
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/acceptedVersion
dc.relation.projectID
info:eu-repo/grantAgreement/MINECO/PN I+D/BIO2012‐32151
dc.identifier.doi
https://doi.org/10.1002/jctb.5551
dc.rights.accessLevel
info:eu-repo/semantics/openAccess