The Ultrasound Window Into Vascular Ageing: A Technology Review by the VascAgeNet COST Action

dc.contributor
Institut Català de la Salut
dc.contributor
[Bianchini E] Institute of Clinical Physiology, CNR, Pisa, Italy. [Guala A] Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. CIBERCV, Instituto de Salud Carlos III, Madrid, Spain. [Golemati S] Medical School, National and Kapodistrian University of Athens, Athens, Greece. [Alastruey J] Department of Biomedical Engineering, King’s College London, London, UK. [Climie RE] Menzies Institute for Medical Research, University of Tasmania, Hobart, Tasmania, Australia. INSERM, U970, Paris Cardiovascular Research Center (PARCC), Université de Paris, Hopital Europeen Georges Pompidou – APHP, Paris, France. [Dalakleidi K] Biomedical Simulations and Imaging (BIOSIM) Laboratory, School of Electrical and Computer Engineering, National Technical University of Athens, Athens, Greece
dc.contributor
Vall d'Hebron Barcelona Hospital Campus
dc.contributor.author
Golemati, Spyretta
dc.contributor.author
Climie, Rachel
dc.contributor.author
BIANCHINI, ELISABETTA
dc.contributor.author
Guala, Andrea
dc.contributor.author
Alastruey, Jordi
dc.contributor.author
Dalakleidi, Kalliopi
dc.date.accessioned
2025-10-24T08:56:21Z
dc.date.available
2025-10-24T08:56:21Z
dc.date.issued
2023-10-03T12:07:51Z
dc.date.issued
2023-10-03T12:07:51Z
dc.date.issued
2023-10
dc.identifier
Bianchini E, Guala A, Golemati S, Alastruey J, Climie RE, Dalakleidi K, et al. The Ultrasound Window Into Vascular Ageing: A Technology Review by the VascAgeNet COST Action. J Ultrasound Med. 2023 Oct;42(10):2183–213.
dc.identifier
0278-4297
dc.identifier
https://hdl.handle.net/11351/10404
dc.identifier
10.1002/jum.16243
dc.identifier
37148467
dc.identifier
000981994400001
dc.identifier.uri
http://hdl.handle.net/11351/10404
dc.description.abstract
Arteriosclerosis; Ultrasound; Vascular ageing
dc.description.abstract
Arteriosclerosi; Ecografia; Envelliment vascular
dc.description.abstract
Arteriosclerosis; Ecografía; Envejecimiento vascular
dc.description.abstract
Non-invasive ultrasound (US) imaging enables the assessment of the properties of superficial blood vessels. Various modes can be used for vascular characteristics analysis, ranging from radiofrequency (RF) data, Doppler- and standard B/M-mode imaging, to more recent ultra-high frequency and ultrafast techniques. The aim of the present work was to provide an overview of the current state-of-the-art non-invasive US technologies and corresponding vascular ageing characteristics from a technological perspective. Following an introduction about the basic concepts of the US technique, the characteristics considered in this review are clustered into: 1) vessel wall structure; 2) dynamic elastic properties, and 3) reactive vessel properties. The overview shows that ultrasound is a versatile, non-invasive, and safe imaging technique that can be adopted for obtaining information about function, structure, and reactivity in superficial arteries. The most suitable setting for a specific application must be selected according to spatial and temporal resolution requirements. The usefulness of standardization in the validation process and performance metric adoption emerges. Computer-based techniques should always be preferred to manual measures, as long as the algorithms and learning procedures are transparent and well described, and the performance leads to better results. Identification of a minimal clinically important difference is a crucial point for drawing conclusions regarding robustness of the techniques and for the translation into practice of any biomarker.
dc.description.abstract
This article is based upon work from COST Action CA18216 VascAgeNet, supported by COST (European Cooperation in Science and Technology, www.cost.eu). A.G. has received funding from “La Caixa” Foundation (LCF/BQ/PR22/11920008). R.E.C is supported by the National Health and Medical Research Council of Australia (reference: 2009005) and by a National Heart Foundation Future Leader Fellowship (reference: 105636). J.A. acknowledges support from the British Heart Foundation [PG/15/104/31913], the Wellcome EPSRC Centre for Medical Engineering at King's College London [WT 203148/Z/16/Z], and the Cardiovascular MedTech Co-operative at Guy's and St Thomas' NHS Foundation Trust [MIC-2016-019].
dc.format
application/pdf
dc.format
application/pdf
dc.language
eng
dc.publisher
Wiley
dc.relation
Journal of Ultrasound in Medicine;42(10)
dc.relation
https://doi.org/10.1002/jum.16243
dc.rights
Attribution-NonCommercial-NoDerivatives 4.0 International
dc.rights
http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Scientia
dc.subject
Artèries - Ecografia
dc.subject
Sistema cardiovascular - Envelliment
dc.subject
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Diagnosis::Diagnostic Techniques and Procedures::Diagnostic Imaging::Ultrasonography
dc.subject
ANATOMY::Cardiovascular System::Blood Vessels::Arteries
dc.subject
Other subheadings::Other subheadings::Other subheadings::/diagnostic imaging
dc.subject
TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::diagnóstico::técnicas y procedimientos diagnósticos::diagnóstico por imagen::ecografía
dc.subject
ANATOMÍA::sistema cardiovascular::vasos sanguíneos::arterias
dc.subject
Otros calificadores::Otros calificadores::Otros calificadores::/diagnóstico por imagen
dc.title
The Ultrasound Window Into Vascular Ageing: A Technology Review by the VascAgeNet COST Action
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)