Dynamic Rule-Based Algorithm to Tune Insulin-on-Board Constraints for a Hybrid Artificial Pancreas System

Otros/as autores/as

Ministerio de Economía y Competitividad (Espanya)

Fecha de publicación

2020



Resumen

The artificial pancreas (AP) is a system intended to control blood glucose levels through automated insulin infusion, reducing the burden of subjects with type 1 diabetes to manage their condition. To increase patients’ safety, some systems limit the allowed amount of insulin active in the body, known as insulin-on-board (IOB). The safety auxiliary feedback element (SAFE) layer has been designed previously to avoid overreaction of the controller and thus avoiding hypoglycemia. In this work, a new method, so-called “dynamic rule-based algorithm,” is presented in order to adjust the limits of IOB in real time. The algorithm is an extension of a previously designed method which aimed to adjust the limits of IOB for a meal with 60 grams of carbohydrates (CHO). The proposed method is intended to be applied on hybrid AP systems during 24 h operation. It has been designed by combining two different strategies to set IOB limits for different situations: (1) fasting periods and (2) postprandial periods, regardless of the size of the meal. The UVa/Padova simulator is considered to assess the performance of the method, considering challenging scenarios. In silico results showed that the method is able to reduce the time spent in hypoglycemic range, improving patients’ safety, which reveals the feasibility of the approach to be included in different control algorithms


This work has been partially funded by the Spanish Government (grant no. DPI2016-78831-C2-2-R), National Counsel of Technological and Scientific Development, CNPq-Brazil (grant nos. 207688/2014-1 and 202050/2015-7), and Formación de Professorado Universitario (grant no. FPU0244 2015)

Tipo de documento

Artículo


Versión publicada


peer-reviewed

Lengua

Inglés

Publicado por

Hindawi

Documentos relacionados

info:eu-repo/semantics/altIdentifier/doi/10.1155/2020/1414597

info:eu-repo/semantics/altIdentifier/issn/2040-2295

info:eu-repo/semantics/altIdentifier/eissn/2040-2309

DPI2016-78831-C2-2-R

info:eu-repo/grantAgreement/MINECO/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DPI2016-78831-C2-2-R/ES/Soluciones para la Mejora de la Eficiencia y Seguridad del Páncreas Artificial mediante Arquitecturas de Control Multivariable Tolerantes a Fallos/

Citación recomendada

Esta citación se ha generado automáticamente.

Derechos

Attribution 4.0 International

http://creativecommons.org/licenses/by/4.0/

Este ítem aparece en la(s) siguiente(s) colección(ones)