Accuracy of Continuous Glucose Monitoring before, during, and after Aerobic and Anaerobic Exercise in Patients with Type 1 Diabetes Mellitus

Altres autors/es

Ministerio de Economía y Competitividad (Espanya)

Data de publicació

2018-03-09



Resum

Continuous glucose monitoring (CGM) plays an important role in treatment decisions for patients with type 1 diabetes under conventional or closed-loop therapy. Physical activity represents a great challenge for diabetes management as well as for CGM systems. In this work, the accuracy of CGM in the context of exercise is addressed. Six adults performed aerobic and anaerobic exercise sessions and used two Medtronic Paradigm Enlite-2 sensors under closed-loop therapy. CGM readings were compared with plasma glucose during different periods: one hour before exercise, during exercise, and four hours after the end of exercise. In aerobic sessions, the median absolute relative difference (MARD) increased from 9.5% before the beginning of exercise to 16.5% during exercise (p < 0.001), and then decreased to 9.3% in the first hour after the end of exercise (p < 0.001). For the anaerobic sessions, the MARD before exercise was 15.5% and increased without statistical significance to 16.8% during exercise realisation (p = 0.993), and then decreased to 12.7% in the first hour after the cessation of anaerobic activities (p = 0.095). Results indicate that CGM might present lower accuracy during aerobic exercise, but return to regular operation a few hours after exercise cessation. No significant impact for anaerobic exercise was found


This project was partially supported by the Spanish Government through grants DPI2013-46982-C2-1-R, DPI2013-46982-C2-2-R, DPI2016-78831-C2-1-R, and DPI2016-78831-C2-2-R, and by the National Council of Technological and Scientific Development, CNPq Brazil through grants 202050/2015-7 and 207688/2014-1

Tipus de document

Article


Versió publicada


peer-reviewed

Llengua

Anglès

Publicat per

MDPI (Multidisciplinary Digital Publishing Institute)

Documents relacionats

info:eu-repo/semantics/altIdentifier/doi/10.3390/bios8010022

info:eu-repo/semantics/altIdentifier/eissn/2079-6374

DPI2013‐46982‐C2‐2‐R

DPI2016-78831-C2-2-R

info:eu-repo/grantAgreement/MINECO//DPI2013-46982-C2-2-R/ES/NUEVOS METODOS PARA LA EFICIENCIA Y SEGURIDAD DEL PANCREAS ARTIFICIAL DOMICILIARIO EN DIABETES TIPO 1/

info:eu-repo/grantAgreement/MINECO/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DPI2016-78831-C2-2-R/ES/Soluciones para la Mejora de la Eficiencia y Seguridad del Páncreas Artificial mediante Arquitecturas de Control Multivariable Tolerantes a Fallos/

Citació recomanada

Aquesta citació s'ha generat automàticament.

Drets

Attribution 3.0 Spain

http://creativecommons.org/licenses/by/3.0/es/

Aquest element apareix en la col·lecció o col·leccions següent(s)