Ministerio de Ciencia e Innovación (Espanya)
Generalitat de Catalunya. Agència de Gestió d'Ajuts Universitaris i de Recerca
info:eu-repo/date/embargoEnd/2026-01-01
info:eu-repo/date/embargoEnd/2026-01-01
2015-01-01
Traditional type 1 diabetes therapies are prone to show poor glucose regulation especially in the postprandial period owing to both physiological and technological limitations. Although a closed-loop controller for glucose regulation has to be tuned to minimize the postprandial excursion and avoid late hypoglycemia, the intrinsic limitations of the problem lead to a trade-off between postprandial peak and late hypoglycemia risk. This paper reveals through an intensive in-silico study with multiple controller tuning combinations that a novel safety layer for glucose controllers, the so-called SAFE loop (Revert et al., 2013), not only reduces the hypoglycemia events but also allows reducing the postprandial glucose excursion, thus breaking the implicit trade-off present in single controllers. The SAFE outer loop monitors the estimated amount of insulin on board, and modifies the control action if it is close to a unique constraint which can be adjusted with clinical criteria. A very challenging test scenario is here implemented including the rate of blood glucose appearance from intakes of mixed meals, diurnal and day-to-day time-varying metabolic changes, inherent drawbacks in sensor and actuator, and other realistic conditions. The results show a significant reduction of hypoglycemia events when SAFE is added, regardless the closed-loop glucose controller, together with a potential postprandial response improvement
Research in this area is partially supported by the Spanish Ministry of Science and Innovation through grant DPI2010-20764-C02, the Government of Catalonia trough grant SGR00523, and the Argentinean Government (ANPCyT PICT-2011-0888 and 2012-0037, CONICET PIP112-2011-00361 and UNLP 1164). Fabian Leon-Vargas acknowledges the FI grants of the Government of Catalonia
Article
Versió publicada
Anglès
Glucèmia; Blood sugar; Hipoglucèmia; Hypoglycemia; Diabetis; Diabetes; Control, Teoria de; Control theory; Anàlisi de sistemes; System analysis; Control intel·ligent; Intelligent control systems; Control automàtic; Automatic control
Elsevier
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.bspc.2014.10.003
info:eu-repo/semantics/altIdentifier/issn/1746-8094
info:eu-repo/grantAgreement/MICINN//DPI2010-20764-C02-02/ES/NUEVAS ESTRATEGIAS DE CONTROL GLUCEMICO POSTPRANDIAL MEDIANTE TERAPIA CON BOMBA DE INSULINA EN DIABETES TIPO 1/
AGAUR/2009-2014/2009 SGR-523
Tots els drets reservats