Quantification of Cervical Cord Cross-Sectional Area: Which Acquisition, Vertebra Level, and Analysis Software? A Multicenter Repeatability Study on a Traveling Healthy Volunteer

dc.contributor
Institut Català de la Salut
dc.contributor
[Lukas C, Bellenberg B] Institute of Neuroradiology, St. Josef Hospital, Ruhr-University Bochum, Bochum, Germany. [Prados F] Department of Medical Physics and Biomedical Engineering, Centre for Medical Image Computing (CMIC), University College London, London, United Kingdom. Queen Square Multiple Sclerosis Centre, UCL Queen Square Institute of Neurology, University College London, London, United Kingdom. e-Health Centre, Universitat Oberta de Catalunya, Barcelona, Spain. [Valsasina P] Neuroimaging Research Unit, Division of Neuroscience, IRCCS San Raffaele Scientific Institute, Milan, Italy. [Parmar K] Neurological Clinic and Policlinic, Department of Medicine, University Hospital Basel, Basel, Switzerland. [Brouwer I] Department of Radiology and Nuclear Medicine, Multiple Sclerosis Center Amsterdam, Amsterdam Neuroscience Amsterdam University Medical Centers (UMC), Vrije Universiteit Medical Center (VUmc), Amsterdam, Netherlands. [Pareto D, Rovira À] Secció de Neuroradiologia, Servei de Radiologia, Vall d'Hebron Hospital Universitari, Barcelona, Spain. [Sastre-Garriga J] Servei de Neurologia–Neuroimmunologia, Centre d'Esclerosi Múltiple de Catalunya (CEMCAT), Barcelona, Spain. Vall d'Hebron Hospital Universitari, Barcelona, Spain
dc.contributor
Vall d'Hebron Barcelona Hospital Campus
dc.contributor.author
Lukas, Carsten
dc.contributor.author
Bellenberg, Barbara
dc.contributor.author
Prados, Ferran
dc.contributor.author
Valsasina, Paola
dc.contributor.author
Parmar, Katrin
dc.contributor.author
Brouwer, Iman
dc.contributor.author
Pareto Onghena, Deborah
dc.contributor.author
Rovira Cañellas, Alex
dc.contributor.author
Sastre Garriga, Jaume
dc.date.accessioned
2025-10-24T10:24:02Z
dc.date.available
2025-10-24T10:24:02Z
dc.date.issued
2022-05-02T12:10:12Z
dc.date.issued
2022-05-02T12:10:12Z
dc.date.issued
2021-08
dc.identifier
Lukas C, Bellenberg B, Prados F, Valsasina P, Parmar K, Brouwer I, et al. Quantification of Cervical Cord Cross-Sectional Area: Which Acquisition, Vertebra Level, and Analysis Software? A Multicenter Repeatability Study on a Traveling Healthy Volunteer. Front Neurol. 2021 Aug;12:693333.
dc.identifier
1664-2295
dc.identifier
https://hdl.handle.net/11351/7422
dc.identifier
10.3389/fneur.2021.693333
dc.identifier
34421797
dc.identifier
000685051800003
dc.identifier.uri
http://hdl.handle.net/11351/7422
dc.description.abstract
Atrofia; Área transversal; Médula espinal
dc.description.abstract
Atròfia; Àrea transversal; Medul·la espinal
dc.description.abstract
Atrophy; Cross-sectional area; Spinal cord
dc.description.abstract
Background: Considerable spinal cord (SC) atrophy occurs in multiple sclerosis (MS). While MRI-based techniques for SC cross-sectional area (CSA) quantification have improved over time, there is no common agreement on whether to measure at single vertebral levels or across larger regions and whether upper SC CSA can be reliably measured from brain images. Aim: To compare in a multicenter setting three CSA measurement methods in terms of repeatability at different anatomical levels. To analyze the agreement between measurements performed on the cervical cord and on brain MRI. Method: One healthy volunteer was scanned three times on the same day in six sites (three scanner vendors) using a 3T MRI protocol including sagittal 3D T1-weighted imaging of the brain (covering the upper cervical cord) and of the SC. Images were analyzed using two semiautomated methods [NeuroQLab (NQL) and the Active Surface Model (ASM)] and the fully automated Spinal Cord Toolbox (SCT) on different vertebral levels (C1–C2; C2/3) on SC and brain images and the entire cervical cord (C1–C7) on SC images only. Results: CSA estimates were significantly smaller using SCT compared to NQL and ASM (p < 0.001), regardless of the cord level. Inter-scanner repeatability was best in C1–C7: coefficients of variation for NQL, ASM, and SCT: 0.4, 0.6, and 1.0%, respectively. CSAs estimated in brain MRI were slightly lower than in SC MRI (all p ≤ 0.006 at the C1–C2 level). Despite protocol harmonization between the centers with regard to image resolution and use of high-contrast 3D T1-weighted sequences, the variability of CSA was partly scanner dependent probably due to differences in scanner geometry, coil design, and details of the MRI parameter settings. Conclusion: For CSA quantification, dedicated isotropic SC MRI should be acquired, which yielded best repeatability in the entire cervical cord. In the upper part of the cervical cord, use of brain MRI scans entailed only a minor loss of CSA repeatability compared to SC MRI. Due to systematic differences between scanners and the CSA quantification software, both should be kept constant within a study. The MRI dataset of this study is available publicly to test new analysis approaches.
dc.description.abstract
Parts of this work were funded by the German Federal Ministry for Education and Research, BMBF, German Competence Network Multiple Sclerosis KKNMS (Grant Nos. 01GI1601I and 01GI0914) and by grants from the UK MS Society. FP, CG, and MY were supported by the National Institute for Health Research (NIHR) University College London Hospitals Biomedical Research Center. The funding institutions did not interfere with the study design, the collection, analysis and interpretation of data, the writing of the report, or the decision to submit the article for publication.
dc.format
application/pdf
dc.format
application/pdf
dc.language
eng
dc.publisher
Frontiers Media
dc.relation
Frontiers in Neurology;12
dc.relation
https://doi.org/10.3389/fneur.2021.693333
dc.rights
Attribution 4.0 International
dc.rights
http://creativecommons.org/licenses/by/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Scientia
dc.subject
Medul·la espinal - Imatgeria
dc.subject
Esclerosi múltiple
dc.subject
Imatgeria per ressonància magnètica
dc.subject
ANATOMY::Nervous System::Central Nervous System::Spinal Cord::Cervical Cord
dc.subject
Other subheadings::Other subheadings::Other subheadings::/diagnostic imaging
dc.subject
DISEASES::Nervous System Diseases::Autoimmune Diseases of the Nervous System::Demyelinating Autoimmune Diseases, CNS::Multiple Sclerosis
dc.subject
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Diagnosis::Diagnostic Techniques and Procedures::Diagnostic Imaging::Tomography::Magnetic Resonance Imaging
dc.subject
ANATOMÍA::sistema nervioso::sistema nervioso central::médula espinal::médula cervical
dc.subject
Otros calificadores::Otros calificadores::Otros calificadores::/diagnóstico por imagen
dc.subject
ENFERMEDADES::enfermedades del sistema nervioso::enfermedades autoinmunitarias del sistema nervioso::enfermedades autoinmunes desmielinizantes del SNC::esclerosis múltiple
dc.subject
TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::diagnóstico::técnicas y procedimientos diagnósticos::diagnóstico por imagen::tomografía::imagen por resonancia magnética
dc.title
Quantification of Cervical Cord Cross-Sectional Area: Which Acquisition, Vertebra Level, and Analysis Software? A Multicenter Repeatability Study on a Traveling Healthy Volunteer
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Fitxers en aquest element

FitxersGrandàriaFormatVisualització

No hi ha fitxers associats a aquest element.

Aquest element apareix en la col·lecció o col·leccions següent(s)