dc.contributor
[Sararols L, Guarro M] OMIQ Research, Sabadell, Barcelona, Spain. Hospital General de Granollers, Granollers, Spain. [Vázquez M, Ruiz S, López E, Biarnés M] OMIQ Research, Sabadell, Barcelona, Spain
dc.contributor
Hospital General de Granollers
dc.contributor.author
Guarro, Merce
dc.contributor.author
Vázquez, Meritxell
dc.contributor.author
Ruiz, Sergi
dc.contributor.author
López, Elena
dc.contributor.author
Sararols Ramsay, Laura
dc.contributor.author
Biarnés, Marc
dc.date.accessioned
2026-02-13T20:28:20Z
dc.date.available
2026-02-13T20:28:20Z
dc.date.issued
2026-02-12T12:19:09Z
dc.date.issued
2026-02-12T12:19:09Z
dc.date.issued
2024-10-24
dc.identifier
Sararols L, Guarro M, Vázquez M, Ruiz S, López E, Biarnés M. Visual Outcomes Following Non-Diffractive Extended-Depth-of-Focus Intraocular Lens Implantation in Patients with Epiretinal Membrane in One Eye and Bilateral Cataracts. Biomedicines. 2024 Oct 24;12(11):2443.
dc.identifier
http://hdl.handle.net/11351/14245
dc.identifier
10.3390/biomedicines12112443
dc.identifier.uri
http://hdl.handle.net/11351/14245
dc.description.abstract
Cataract; Intraocular lens; Epiretinal membrane
dc.description.abstract
Catarata; Lente intraocular; Membrana epirretiniana
dc.description.abstract
Cataracta; Lent intraocular; Membrana epiretinal
dc.description.abstract
Background/objectives: This study aimed to characterize the visual performance in patients with bilateral cataracts and a unilateral epiretinal membrane (ERM) undergoing cataract surgery with non-diffractive extended depth of focus (EDoF) intraocular lens (IOL) placement in both eyes and phacovitrectomy in the eye with ERM.
Methods: This was a prospective, descriptive, single-arm study. Visual outcomes were measured in monocular and binocular conditions in patients with bilateral cataracts and unilateral ERM stages 2 or 3 implanted with an EDoF IOL. At 6 months, visual acuity (uncorrected and corrected at different distances and contrast levels), contrast sensitivity, and visual disturbances assessed using a Light Distortion Analyzer were determined.
Results: We included 22 patients (50% females, mean age of 71.4 ± 5.8 years). Mean monocular best-corrected visual acuities at 100% contrast were 0.07 ± 0.09, 0.23 ± 0.10, and 0.48 ± 0.14 logMAR for eyes with ERM, and 0.02 ± 0.08, 0.19 ± 0.11, and 0.41 ± 0.18 logMAR for fellow eyes for far, intermediate, and near distance vision, respectively. No differences were observed in visual outcomes, contrast sensitivity, or visual disturbances between ERM and non-ERM eyes, except for near distance. No unexpected adverse events were observed.
Conclusions: Non-diffractive EDoF IOL can be considered in patients with cataracts and stage 2 or 3 ERM pursuing spectacle independence.
dc.format
application/pdf
dc.relation
Biomedicines;12(11)
dc.relation
https://doi.org/10.3390/biomedicines12112443
dc.rights
Attribution 4.0 International
dc.rights
http://creativecommons.org/licenses/by/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.subject
Cataractes - Cirurgia
dc.subject
Lents intraoculars
dc.subject
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Surgical Procedures, Operative::Ophthalmologic Surgical Procedures::Refractive Surgical Procedures::Cataract Extraction
dc.subject
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Surgical Procedures, Operative::Ophthalmologic Surgical Procedures::Refractive Surgical Procedures::Lens Implantation, Intraocular
dc.subject
DISEASES::Eye Diseases::Retinal Diseases::Epiretinal Membrane
dc.subject
TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::intervenciones quirúrgicas::procedimientos quirúrgicos oftalmológicos::procedimientos quirúrgicos refractivos::extracción de catarata
dc.subject
TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::intervenciones quirúrgicas::procedimientos quirúrgicos oftalmológicos::procedimientos quirúrgicos refractivos::implantación de lentes intraoculares
dc.subject
ENFERMEDADES::oftalmopatías::enfermedades de la retina::membrana epirretiniana
dc.title
Visual Outcomes Following Non-Diffractive Extended-Depth-of-Focus Intraocular Lens Implantation in Patients with Epiretinal Membrane in One Eye and Bilateral Cataracts
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion