Automated segmentation of thoracic aortic lumen and vessel wall on three-dimensional bright- and black-blood magnetic resonance imaging using nnU-Net

dc.contributor
Institut Català de la Salut
dc.contributor
[Cesario M] School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom. Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre, Maastricht, the Netherlands. Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, the Netherlands. [Littlewood SJ, Fletcher TJ, Fotaki A] School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom. [Nadel J] School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom. Clinical Research Group, Heart Research Institute, Newtown, Australia. Cardiology Department, St. Vincent’s Hospital, Darlinghurst, Australia. [Castillo-Passi C] School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom. Institute of Biological and Medical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile. [Olivero R, Rodríguez-Palomares J] Servei de Cardiologia, Vall d′Hebron Hospital Universitari, Barcelona, Spain. Departament de Medicina, Universitat Autònoma de Barcelona, Bellaterra, Spain. Grup de Recerca de Malalties Cardiovasculars, Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. Universitat Autònoma de Barcelona, Bellaterra, Spain. CIBER de Enfermedades Cardiovasculares, Instituto de Salud Carlos III, Madrid, Spain
dc.contributor
Vall d'Hebron Barcelona Hospital Campus
dc.contributor.author
Cesario, Matteo
dc.contributor.author
Littlewood, Simon
dc.contributor.author
Fletcher, Thomas J.
dc.contributor.author
Fotaki, Anastasia
dc.contributor.author
Castillo-Passi, Carlos
dc.contributor.author
Nadel, James
dc.contributor.author
Oliveró, Ruperto
dc.contributor.author
Rodríguez Palomares, José F
dc.date.accessioned
2025-10-01T01:28:10Z
dc.date.available
2025-10-01T01:28:10Z
dc.date.issued
2025-08-06T08:06:47Z
dc.date.issued
2025-08-06T08:06:47Z
dc.date.issued
2025
dc.identifier
Cesario M, Littlewood SJ, Nadel J, Fletcher TJ, Fotaki A, Castillo-Passi C, et al. Automated segmentation of thoracic aortic lumen and vessel wall on three-dimensional bright- and black-blood magnetic resonance imaging using nnU-Net. J Cardiovasc Magn Reson. 2025;27(2):101923.
dc.identifier
1097-6647
dc.identifier
http://hdl.handle.net/11351/13495
dc.identifier
10.1016/j.jocmr.2025.101923
dc.identifier
40513884
dc.identifier.uri
http://hdl.handle.net/11351/13495
dc.description.abstract
Aorta; Magnetic resonance angiography; Segmentation
dc.description.abstract
Aorta; Angiografía por resonancia magnética; Segmentación
dc.description.abstract
Aorta; Angiografia per ressonància magnètica; Segmentació
dc.description.abstract
Background: Magnetic resonance angiography (MRA) is an important tool for aortic assessment in several cardiovascular diseases. Assessment of MRA images relies on manual segmentation, a time-intensive process that is subject to operator variability. We aimed to optimize and validate two deep-learning models for automatic segmentation of the aortic lumen and vessel wall in high-resolution electrocardiogram-triggered free-breathing respiratory motion-corrected three-dimensional (3D) bright- and black-blood MRA images. Methods: Manual segmentation, serving as the ground truth, was performed on 25 bright-blood and 15 black-blood 3D MRA image sets acquired with the iT2PrepIR-BOOST sequence (1.5T) in thoracic aortopathy patients. The training was performed with no new U-Net (nnUNet) for bright-blood (lumen) and black-blood image sets (lumen and vessel wall). Training consisted of a 70:20:10% (17/25:5/25:3/25 datasets) training:validation:testing split. Inference was run on datasets (single vendor) from different centers (UK, Spain, and Australia), sequences (iT2PrepIR-BOOST, T2 prepared coronary magnetic resonance angiography [CMRA], and time-resolved angiography with interleaved stochastic trajectories [TWIST] MRA), acquired resolutions (from 0.9-3 mm3), and field strengths (0.55T, 1.5T, and 3T). Predictive measurements comprised Dice similarity coefficient (DSC) and Intersection over Union (IoU). Postprocessing (3D slicer) included centreline extraction, diameter measurement, and curved planar reformatting (CPR). Results: The optimal configuration was the 3D U-Net. Bright-blood segmentation at 1.5T on iT2PrepIR-BOOST datasets (1.3 and 1.8 mm3) and 3D CMRA datasets (0.9 mm3) resulted in DSC ≥ 0.96 and IoU ≥ 0.92. For bright-blood segmentation on 3D CMRA at 0.55T, the nnUNet achieved DSC and IoU scores of 0.93 and 0.88 at 1.5 mm³, and 0.68 and 0.52 at 3.0 mm³, respectively. DSC and IoU scores of 0.89 and 0.82 were obtained for CMRA image sets (1 mm3) at 1.5T (Barcelona dataset). DSC and IoU scores of the BRnnUNet model were 0.90 and 0.82, respectively, for the contrast-enhanced dataset (TWIST MRA). Lumen segmentation on black-blood 1.5T iT2PrepIR-BOOST image sets achieved DSC ≥ 0.95 and IoU ≥ 0.90, and vessel wall segmentation resulted in DSC ≥ 0.80 and IoU ≥ 0.67. Automated centreline tracking, diameter measurement, and CPR were successfully implemented in all subjects. Conclusion: Automated aortic lumen and wall segmentation on 3D bright- and black-blood image sets demonstrated excellent agreement with ground truth. This technique demonstrates a fast and comprehensive assessment of aortic morphology with great potential for future clinical application in various cardiovascular diseases.
dc.description.abstract
The authors acknowledge financial support from (1) King’s BHF Centre for Award Excellence RE/24/130035 and RG/20/1/34802, (2) EPSRC EP/V044087/1, (3) Wellcome EPSRC Centre for Medical Engineering (NS/A000049/1), (4) Millennium Institute for Intelligent Healthcare Engineering ICN2021_004, FONDECYT 1250261 and 1250252, (5) IMPACT, Center of Interventional Medicine for Precision and Advanced Cellular Therapy, Santiago, Chile. ANID—Basal funding for Scientific and Technological Center of Excellence, IMPACT, #FB210024, (6) the Department of Health through the National Institute for Health Research (NIHR) comprehensive Biomedical Research Centre award, (7) NIHR Cardiovascular MedTech Co-operative and (8) the Technical University of Munich – Institute for Advanced Study. The views expressed are those of the authors and not necessarily those of the BHF, NHS, the NIHR, or the Department of Health. J.N. is supported by the Royal Australasian College of Physicians’ Bushell Travelling Fellowship & a European Association of Cardiovascular Imaging Research Grant.
dc.format
application/pdf
dc.language
eng
dc.publisher
Elsevier
dc.relation
Journal of Cardiovascular Magnetic Resonance;27(2)
dc.relation
https://doi.org/10.1016/j.jocmr.2025.101923
dc.rights
Attribution 4.0 International
dc.rights
http://creativecommons.org/licenses/by/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Scientia
dc.subject
Imatgeria tridimensional en medicina
dc.subject
Aprenentatge profund
dc.subject
Angiografia
dc.subject
Aorta - Imatgeria per ressonància magnètica
dc.subject
Vasos sanguinis - Imatgeria per ressonància magnètica
dc.subject
Sistema cardiovascular - Malalties
dc.subject
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Diagnosis::Diagnostic Techniques and Procedures::Diagnostic Imaging::Tomography::Magnetic Resonance Imaging::Magnetic Resonance Angiography
dc.subject
ANATOMY::Cardiovascular System::Blood Vessels::Arteries::Aorta
dc.subject
Other subheadings::Other subheadings::Other subheadings::/diagnostic imaging
dc.subject
DISEASES::Cardiovascular Diseases
dc.subject
PHENOMENA AND PROCESSES::Mathematical Concepts::Algorithms::Artificial Intelligence::Machine Learning::Deep Learning
dc.subject
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Diagnosis::Diagnostic Techniques and Procedures::Diagnostic Imaging::Imaging, Three-Dimensional
dc.subject
ANATOMY::Cardiovascular System::Blood Vessels::Arteries::Coronary Vessels
dc.subject
TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::diagnóstico::técnicas y procedimientos diagnósticos::diagnóstico por imagen::tomografía::imagen por resonancia magnética::angiografía por resonancia magnética
dc.subject
ANATOMÍA::sistema cardiovascular::vasos sanguíneos::arterias::aorta
dc.subject
Otros calificadores::Otros calificadores::Otros calificadores::/diagnóstico por imagen
dc.subject
ENFERMEDADES::enfermedades cardiovasculares
dc.subject
FENÓMENOS Y PROCESOS::conceptos matemáticos::algoritmos::inteligencia artificial::aprendizaje automático::aprendizaje profundo
dc.subject
TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::diagnóstico::técnicas y procedimientos diagnósticos::diagnóstico por imagen::imagen tridimensional
dc.subject
ANATOMÍA::sistema cardiovascular::vasos sanguíneos::arterias::vasos coronarios
dc.title
Automated segmentation of thoracic aortic lumen and vessel wall on three-dimensional bright- and black-blood magnetic resonance imaging using nnU-Net
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Files in this item