Las placas intrapélvicas suprapectíneas interfieren con la evaluación postoperatoria de la calidad de reducción por radiografía simple. Hallazgos sobre una serie retrospectiva de fracturas de acetábulo

Intrapelvic suprapectineal acetabular plates interfere with the quality of reduction evaluations on postoperative X-rays. A retrospective case series

dc.contributor
Institut Català de la Salut
dc.contributor
[Andrés-Peiró JV, Tomás-Hernández J, Selga-Marsá J, Piedra-Calle CA, García-Sánchez Y, Teixidor-Serra J] Servei de Cirurgia Ortopèdica i Traumatologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain. Grup de Recerca en Cirurgia Reconstructiva de l’Aparell Locomotor, Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. [Lloret-Peiró C, Bustos-Mardones A, Martínez-Collado P] Servei de Cirurgia Ortopèdica i Traumatologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain
dc.contributor
Vall d'Hebron Barcelona Hospital Campus
dc.contributor.author
Lloret Peiró, Cristina
dc.contributor.author
Bustos-Mardones, Andrés
dc.contributor.author
Tomás-Hernández, Jordi
dc.contributor.author
Piedra Calle, Carlos Alberto
dc.contributor.author
Teixidor Serra, Jordi
dc.contributor.author
Andrés Peiró, José Vicente
dc.contributor.author
Martinez Collado, Pablo
dc.contributor.author
Selga Marsa, Jordi
dc.contributor.author
Garcia-Sanchez, Yaiza
dc.date.accessioned
2025-05-18T20:42:40Z
dc.date.available
2025-05-18T20:42:40Z
dc.date.issued
2025-05-16T12:13:10Z
dc.date.issued
2025-05-16T12:13:10Z
dc.date.issued
2024
dc.date.issued
2025-05
dc.identifier
Vicente Andrés-Peiró J, Lloret-Peiró C, Bustos-Mardones A, Martínez-Collado P, Tomás-Hernández J, Selga-Marsá J, et al. Las placas intrapélvicas suprapectíneas interfieren con la evaluación postoperatoria de la calidad de reducción por radiografía simple. Hallazgos sobre una serie retrospectiva de fracturas de acetábulo. Rev Esp Cir Ortop Traumatol. 2025 May;69(3):267-73.
dc.identifier
1888-4415
dc.identifier
http://hdl.handle.net/11351/13100
dc.identifier
10.1016/j.recot.2024.10.004
dc.identifier
39393486
dc.identifier.uri
http://hdl.handle.net/11351/13100
dc.description.abstract
Fractura de acetábulo; Placa intrapélvica suprapectínea; Calidad de reducción
dc.description.abstract
Acetabular fracture; Intrapelvic suprapectineal plate; Quality of reduction
dc.description.abstract
Fractura d'acetàbul; Placa intrapèlvica suprapectínia; Qualitat de reducció
dc.description.abstract
Introducción Las placas intrapélvicas suprapectíneas juegan un importante papel en la osteosíntesis moderna de las fracturas del acetábulo. Sin embargo, la particular forma de estos implantes puede interferir con la valoración de la calidad de reducción utilizando radiografías simples (RX). En este trabajo, buscamos evaluar este artefacto y su relación con los hallazgos de la tomografía computarizada (TC). Materiales y métodos En una serie retrospectiva y unicéntrica de 22 fracturas acetabulares, las RX en proyecciones anteroposterior, alar y obturatriz; así como las imágenes de TC, fueron valoradas por 3 evaluadores independientes. Se utilizó el coeficiente Kappa de Cohen para analizar la concordancia entre observadores. Resultados Las placas suprapectíneas interfirieron con la valoración de la calidad de la reducción en la superficie de carga de un 75,3% de evaluaciones, y con las 3 proyecciones en un 43,9% de los casos. El segmento central fue el más consistentemente afectado, correspondiendo al área donde se observó el mayor desplazamiento residual en un 46,9% de cortes coronales y un 42,4% de cortes sagitales de TC. Conclusiones Dado que la calidad de la reducción tiene valor pronóstico y es una información necesaria para guiar el desempeño del equipo quirúrgico, debería valorarse complementar la RX con la TC en el examen postoperatorio de las fracturas acetabulares más complejas.
dc.description.abstract
Introduction Intrapelvic suprapectineal plates play an important role in acetabular fracture fixation. However, the shape of these implants may interfere with the quality of reduction evaluations using plain X-rays. We sought to evaluate this artifact and its relationship with CT findings. Materials and methods In a retrospective, single-center series of 22 acetabular fractures, postoperative AP, alar and obturator X-ray views and CT images were evaluated by three independent observers. Cohen's kappa was used to examine interrater reliability. Results Suprapectineal plates interfered with the evaluation of the weight-bearing surface in 75.3%, and with all three oblique views in 43.9% of cases. The central segment was most consistently interfered with, corresponding to the area where the greatest malreduction was in 46.9% coronal and 42.4% of sagittal CT views. Conclusions Since the quality of reduction has prognostic value and is a necessary guide for the surgical team, that CT may be considered for the postoperative examination of the most challenging acetabular fracture cases.
dc.format
application/pdf
dc.language
spa
dc.publisher
Elsevier
dc.relation
Revista Española de Cirugía Ortopédica y Traumatología;69(3)
dc.relation
https://doi.org/10.1016/j.recot.2024.10.004
dc.rights
Attribution-NonCommercial-NoDerivatives 4.0 International
dc.rights
http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Scientia
dc.subject
Avaluació de resultats (Assistència sanitària)
dc.subject
Osteosíntesi
dc.subject
Acetàbul (Anatomia) - Fractures
dc.subject
Tomografia
dc.subject
Diagnòstic radiològic
dc.subject
DISEASES::Wounds and Injuries::Fractures, Bone
dc.subject
ANATOMY::Musculoskeletal System::Skeleton::Bone and Bones::Bones of Lower Extremity::Pelvic Bones::Acetabulum
dc.subject
Other subheadings::Other subheadings::/injuries
dc.subject
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Equipment and Supplies::Prostheses and Implants::Internal Fixators::Bone Plates
dc.subject
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Diagnosis::Diagnostic Techniques and Procedures::Diagnostic Imaging::Image Interpretation, Computer-Assisted::Tomography, X-Ray Computed
dc.subject
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Diagnosis::Prognosis::Treatment Outcome
dc.subject
ENFERMEDADES::heridas y lesiones::fracturas óseas
dc.subject
ANATOMÍA::sistema musculoesquelético::esqueleto::huesos::huesos de la extremidad inferior::huesos pélvicos::acetábulo
dc.subject
Otros calificadores::Otros calificadores::/lesiones
dc.subject
TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::equipos y suministros::prótesis e implantes::fijadores internos::placas óseas
dc.subject
TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::diagnóstico::técnicas y procedimientos diagnósticos::diagnóstico por imagen::interpretación de imágenes asistida por ordenador::tomografía computarizada por rayos X
dc.subject
TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::diagnóstico::pronóstico::resultado del tratamiento
dc.title
Las placas intrapélvicas suprapectíneas interfieren con la evaluación postoperatoria de la calidad de reducción por radiografía simple. Hallazgos sobre una serie retrospectiva de fracturas de acetábulo
dc.title
Intrapelvic suprapectineal acetabular plates interfere with the quality of reduction evaluations on postoperative X-rays. A retrospective case series
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Fitxers en aquest element

FitxersGrandàriaFormatVisualització

No hi ha fitxers associats a aquest element.

Aquest element apareix en la col·lecció o col·leccions següent(s)