Geometric, Biomechanic and Haemodynamic Aortic Abnormalities Assessed by 4D Flow Cardiovascular Magnetic Resonance in Patients Treated by TEVAR Following Blunt Traumatic Thoracic Aortic Injury

dc.contributor
Institut Català de la Salut
dc.contributor
[Gil-Sala D, Goncalves Martins G, Bellmunt S] Servei d’Angiologia, Cirurgia Vascular i Endovascular, Vall d’Hebron Hospital Universitari, Barcelona, Spain. Departament de Cirurgia, Universitat Autònoma de Barcelona, Bellaterra, Spain. [Guala A, Ruiz Muñoz A] Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. CIBER-CV, Instituto de Salud Carlos III (ISCIII), Madrid, Spain. [Garcia Reyes ME, Allegue Allegue N, Constenla García I, Tello Díaz C] Servei d’Angiologia, Cirurgia Vascular i Endovascular, Vall d’Hebron Hospital Universitari, Barcelona, Spain. [Azancot MA] Servei de Nefrologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain. [Dux-Santoy L] Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. [Teixido Turà G, Rodríguez-Palomares JF] Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. CIBER-CV, Instituto de Salud Carlos III (ISCIII), Madrid, Spain. Servei de Cardiologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain. [Evangelista A] Departament de Cirurgia, Universitat Autònoma de Barcelona, Bellaterra, Spain. Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. CIBER-CV, Instituto de Salud Carlos III (ISCIII), Madrid, Spain. Servei de Cardiologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain. Instituto del Corazón, Quirónsalud-Teknon, Barcelona, Spain. [Ferreira González I] Servei de Cardiologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain. CIBER-ESP, Instituto de Salud Carlos III, Madrid, Spain. Universitat Autònoma de Barcelona, Bellaterra, Spain
dc.contributor
Vall d'Hebron Barcelona Hospital Campus
dc.contributor.author
Gil-Sala, Daniel
dc.contributor.author
García Reyes, Marvin Ernesto
dc.contributor.author
Azancot Rivero, M Antonieta
dc.contributor.author
Allegue Allegue, Nicolás
dc.contributor.author
Gonçalves Martins, Gabriela
dc.contributor.author
Constenla García, Ivan
dc.contributor.author
Tello-Díaz, Cristina
dc.contributor.author
Ferreira González, Ignacio
dc.contributor.author
Guala, Andrea
dc.contributor.author
Dux-Santoy Hurtado, Lydia
dc.contributor.author
Teixido-Tura, Gisela
dc.contributor.author
Ruiz Muñoz, Aroa
dc.contributor.author
Evangelista Masip, Arturo
dc.contributor.author
Rodríguez Palomares, José F
dc.contributor.author
Bellmunt-Montoya, Sergi
dc.date.accessioned
2025-02-04T14:37:23Z
dc.date.available
2025-02-04T14:37:23Z
dc.date.issued
2025-01-24T09:05:52Z
dc.date.issued
2025-01-24T09:05:52Z
dc.date.issued
2021-11
dc.identifier
Gil-Sala D, Guala A, Garcia Reyes ME, Azancot MA, Dux-Santoy L, Allegue Allegue N, et al. Geometric, Biomechanic and Haemodynamic Aortic Abnormalities Assessed by 4D Flow Cardiovascular Magnetic Resonance in Patients Treated by TEVAR Following Blunt Traumatic Thoracic Aortic Injury. Eur J Vasc Endovasc Surg. 2021 Nov;62(5):797–807.
dc.identifier
1532-2165
dc.identifier
https://hdl.handle.net/11351/12476
dc.identifier
10.1016/j.ejvs.2021.07.016
dc.identifier
34511317
dc.identifier
000727267700022
dc.identifier.uri
http://hdl.handle.net/11351/12476
dc.description.abstract
Haemodynamics; Magnetic resonance imaging; Thoracic aorta
dc.description.abstract
Hemodinámica; Imagen por resonancia magnética; Aorta torácica
dc.description.abstract
Hemodinàmica; Imatge per ressonància magnètica; Aorta toràcica
dc.description.abstract
Objective Thoracic endovascular aortic repair (TEVAR) is widely used for the treatment of patients with blunt traumatic thoracic aortic injury (BTAI). However, aortic haemodynamic and biomechanical implications of this intervention are poorly investigated. This study aimed to assess whether patients treated by TEVAR following BTAI have thoracic aortic abnormalities in geometry, stiffness, and haemodynamics. Methods Patients with BTAI treated by TEVAR at Vall d’Hebron Hospital between 1999 and 2019 were compared with propensity score matched healthy volunteers (HVs). All subjects underwent cardiovascular magnetic resonance (CMR) comprising a 4D flow CMR sequence. Spatially resolved aortic diameter, length, volume, and curvature were assessed. Pulse wave velocity, distensibility, and longitudinal strain (all measurements of aortic stiffness) were determined regionally. Moreover, advanced haemodynamic descriptors were quantified: systolic flow reversal ratio (SFRR), quantifying backward flow during systole, and in plane rotational flow (IRF), measuring in plane strength of helical flow. Results Twenty-six BTAI patients treated by TEVAR were included and matched with 26 HVs. They did not differ in terms of age, sex, and body surface area. Patients with TEVAR had a larger and longer ascending aorta (AAo) and marked abnormalities in local curvature. Aortic stiffness was greater in the aortic segments proximal and distal to TEVAR compared with controls. Moreover, TEVAR patients presented strongly altered flow dynamics compared with controls: a reduced IRF from the distal AAo to the proximal descending aorta and an increased SFRR in the whole thoracic aorta. These differences persisted adjusting for cardiovascular risk factors and were independent of time elapsed since TEVAR implantation. Conclusion At long term follow up, previously healthy patients who underwent TEVAR implantation following BTAI had increased diameter, length and volume of the ascending aorta, and increased aortic stiffness and abnormal flow patterns in the whole thoracic aorta compared with matched controls. Further studies should address whether these alterations have clinical implications.
dc.description.abstract
This study has been funded by the Endovascular Chapter of the Spanish Vascular Surgery Society via “Ayudas a la investigación en cirugía endovascular. Convocatoria 2019”, Instituto de Salud Carlos III through the project PI17/00381 and PI19/01480, La Marató de TV3 (project number 20151330), Ministerio de Economía y Competitividad through Retos-Colaboración 2016 (RTC-2016-5152-1) and Societat Catalana de Cardiologia 2017. Guala A. has received funding from the Spanish Ministry of Science, Innovation and Universities (IJC2018-037349-I).
dc.format
application/pdf
dc.language
eng
dc.publisher
Elsevier
dc.relation
European Journal of Vascular and Endovascular Surgery;62(5)
dc.relation
https://doi.org/10.1016/j.ejvs.2021.07.016
dc.rights
Attribution-NonCommercial-NoDerivatives 4.0 International
dc.rights
http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rights
info:eu-repo/semantics/restrictedAccess
dc.source
Scientia
dc.subject
Aorta - Ferides i lesions - Cirurgia
dc.subject
Aorta - Imatgeria per ressonància magnètica
dc.subject
Avaluació de resultats (Assistència sanitària)
dc.subject
ANATOMY::Cardiovascular System::Blood Vessels::Arteries::Aorta::Aorta, Thoracic
dc.subject
Other subheadings::Other subheadings::Other subheadings::/surgery
dc.subject
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Diagnosis::Diagnostic Techniques and Procedures::Diagnostic Imaging::Tomography::Magnetic Resonance Imaging
dc.subject
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Surgical Procedures, Operative::Cardiovascular Surgical Procedures::Vascular Surgical Procedures::Endovascular Procedures
dc.subject
DISEASES::Wounds and Injuries::Thoracic Injuries
dc.subject
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Diagnosis::Prognosis::Treatment Outcome
dc.subject
ANATOMÍA::sistema cardiovascular::vasos sanguíneos::arterias::aorta::aorta torácica
dc.subject
Otros calificadores::Otros calificadores::Otros calificadores::/cirugía
dc.subject
TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::diagnóstico::técnicas y procedimientos diagnósticos::diagnóstico por imagen::tomografía::imagen por resonancia magnética
dc.subject
TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::intervenciones quirúrgicas::procedimientos quirúrgicos cardiovasculares::procedimientos quirúrgicos vasculares::procedimientos endovasculares
dc.subject
ENFERMEDADES::heridas y lesiones::traumatismos torácicos
dc.subject
TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::diagnóstico::pronóstico::resultado del tratamiento
dc.title
Geometric, Biomechanic and Haemodynamic Aortic Abnormalities Assessed by 4D Flow Cardiovascular Magnetic Resonance in Patients Treated by TEVAR Following Blunt Traumatic Thoracic Aortic Injury
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.